FLA-2 MVI 7005/2 PN16

Data sheet

Materials
  • Pump housing
    5.1301, EN-GJL-250
  • Impeller
    1.4301, X5CrNi18-10
  • Shaft
    1.4057, X20CrNi17-2
  • Gasket material
    EPDM
  • Pipework material
    1.4307, X2CrNi18-9
Operating data
  • Min. fluid temperature T
    3 °C
  • Max. fluid temperature T
    50 °C
  • Max. ambient temperature T
    40 °C
  • Maximum operating pressure p
    16 bar
Motor data
  • Mains connection
    3~400 V, 50 Hz
  • Rated power P2
    30.00 kW
  • Rated current IN
    52.20 A
  • Power factor cos φ
    0.90
  • Activation type
    Star-delta (SD)
  • Protection class control panel
    IP54
  • Protection class motor
    IP55
Installation dimensions
  • Pipe connection on the suction side DNs
    DN 125
  • Pipe connection on the pressure side DNd
    DN 125
Information for order placements
  • Net weight, approx. m
    1143 kg
  • Brand
    Wilo
  • Product description
    FLA-2 MVI 7005/2 PN16
  • Article number
    2536598

Pump curves

FLA-2 MVI7002/1-7606/1

FLA-2 MVI7002/1-7606/1
FLA-2 MVI7002/1-7606/1

Wiring diagram

Ordering information

Information for order placements
  • Brand
    Wilo
  • Product description
    FLA-2 MVI 7005/2 PN16
  • EAN number
    4048482236148
  • Article number
    2536598
  • Gross weight, approx. m
    1323.0 kg
  • Net weight, approx. m
    1143 kg
  • Overall length L
    2200.0 mm
  • Height without packaging H
    1697 mm
  • Colour
    Green/black/silver
  • Packaging property
    Transport packaging
  • Packaging type
    Transport skids
  • Number per layer
    1
  • Width without packaging L
    1606.0 mm
  • Minimum order quantity
    1
  • Pieces per pallet
    1

Tender text

Pressure boosting system to be connected indirectly and fully automatic double pump compact unit as homogeneous redundant version of a single-pump system for fire extinguishing applications.

Consisting of:

Two non-self-priming, multi-stage high-pressure multi-stage centrifugal pumps in vertical design. Impellers and stage housing are made of stainless steel.

IE2 standard motors, 3-phase, 2-pole.

Diaphragm pressure vessel (capacity 8 l), joint tubing on suction and pressure side

per pump: with non-return valve, shut-off valve on suction and pressure side (sealed in opened state), manometer, pressure switch for automatic system control.

Comes as standard with pump protection by means of minimum volume acceptance via bypass without auxiliary energy.

FLA switchgear for fire extinguishing systems in accordance with DIN 14462. Integrated in a steel sheeting housing.

Homogeneously redundant switchgear version without mutual lock, i.e. two complete autonomous working controls with one power supply each for operation of one pump each. Scope of functions and suitability in accordance with DIN 14462 have been proven by TÜV test report.

Per pump with one control consisting of:

Built-in motor protection only for signalling of faults. The motor protection is activated in test run.

Switch for Manual-Automatic mode Control of the pump by pressure switch in automatic mode; expandable to up to eight sensors (in series connection), for example external on/off limit switch etc. (more than eight sensors on request). All sensor signals which could lead to the pump being started are monitored for wire breakage and short circuits.

System with programmable time switch for regular test run.

Dry-running protection relay, for example, for connection of low water float switch from the WILO FLA break tanks, electrodes, pressure switches etc.; low water status only for signalling of faults. The low water is activated in test run.

With signal lamps for operational readiness (green), pump ON (green), fault (red), pump request (white) as well as potential-free contacts for operational readiness and collective fault (possible as common signal) and pump ON.

Suitable for use in industrial and residential areas in accordance with the basic requirements of guideline 2004/108/EC (EMC guideline).

The system has been mounted on the base frame with wires and pipes are ready for connection.

The customer must take suitable measures to ensure that the flow pressure of 8 bar and the resting pressure of 12 bar are not exceeded at any fire hose reel.

Operating data
  • Fluid media
    Water
  • Permitted fluids
    Water
  • Min. fluid temperature T
    3 °C
  • Max. fluid temperature T
    50 °C
  • Max. ambient temperature T
    40 °C
  • Maximum operating pressure p
    16 bar
  • Inlet pressure p inl
    0.98 bar
Motor data
  • Mains connection
    3~400 V, 50 Hz
  • Rated power P2
    30.00 kW
  • Rated current IN
    52.20 A
  • Power factor cos φ
    0.90
  • Activation type
    Star-delta (SD)
  • Protection class control panel
    IP54
  • Protection class motor
    IP55
Materials
  • Pump housing
    5.1301, EN-GJL-250
  • Impeller
    1.4301, X5CrNi18-10
  • Shaft
    1.4057, X20CrNi17-2
  • Gasket material
    EPDM
  • Pipework material
    1.4307, X2CrNi18-9
Installation dimensions
  • Pipe connection on the suction side DNs
    DN 125
  • Pipe connection on the pressure side DNd
    DN 125
Information for order placements
  • Brand
    Wilo
  • Product description
    FLA-2 MVI 7005/2 PN16
  • Net weight, approx. m
    1143 kg
  • Article number
    2536598

Downloads

Wilo-Helix V/ FIRST V 2-4-6-10-16

Article Number 4143727
Edition 1607
Version number 08
Page format A4
Number of pages 17

PDF (5 MB)

Download

Wilo-Helix V/ FIRST V 22-36-52

Article Number 4120943
Edition 1603
Version number 09
Page format A4
Number of pages 1

PDF (116 MB)

Download

Wilo-Helix V/ FIRST V 22-36-52

Article Number 4120943
Edition 1603
Version number 09
Page format A4
Number of pages 15

PDF (4 MB)

Download

Wilo-MultiVert MVI 16../32../52../70../95..

Article Number 2040502
Edition 1606
Version number 08
Page format A4
Number of pages 1

PDF (8 MB)

Download

Wilo-MultiVert MVI 16../32../52../70../95..

Article Number 2040502
Edition 1606
Version number 08
Page format A4
Number of pages 17

PDF (984 kB)

Download

Wilo-Multivert MVI 16../32../52../70../95..

Article Number 2040502
Edition 1606
Version number 08
Page format A4
Number of pages 14

PDF (1 MB)

Download

REACH Regulation

Edition 2018-10
Page format 209.9 x 296.7 mm
Number of pages 4

PDF (581 kB)

Download

PDF: FLA-2 MVI 7005/2 PN16

Configure

Page selection

Format selection

Optional information

You can enter any personal information that you want to be displayed in the header.

Download