Padus UNI M05/T25-540/A

Data sheet

Materials
  • Pump housing
    PP-GF30
  • Motor housing
    1.4301, X5CrNi18-10
  • Gasket material
    NBR
  • Impeller
    PP-GF30
Operating data
  • Min. fluid temperature T
    3 °C
  • Max. fluid temperature T
    40 °C
  • Maximum operating pressure p
    10 bar
  • Max. immersion depth
    7.00 m
Motor data
  • Mains connection
    3~400 V, 50 Hz
  • Rated power P2
    2.50 kW
  • Rated current IN
    5.50 A
  • Power factor cos φ
    0.84
  • Protection class motor
    IP68
Cable
  • Cable type
    H07RN-F
  • Cable cross-section
    6G1 mm²
  • Connection cable length
    10.0 m
Installation dimensions
  • Pipe connection on the pressure side
    G 2
Information for order placements
  • Net weight, approx. m
    26 kg
  • Brand
    Wilo
  • Product description
    Padus UNI M05/T25-540/A
  • Article number
    6084812

Dimensions and dimensions drawings

Wilo-Padus UNI M05

Wilo-Padus UNI M05
Wilo-Padus UNI M05

Pump curves

Wilo-Padus UNI M05 - 50 Hz - No. of poles: 2

Wilo-Padus UNI M05 - 50 Hz - No. of poles: 2

The specified degrees of efficiency correspond to the hydraulic efficiency.

Wilo-Padus UNI M05 - 50 Hz - No. of poles: 2

Wiring diagram

Ordering information

Information for order placements
  • Brand
    Wilo
  • Product description
    Padus UNI M05/T25-540/A
  • EAN number
    4048482858302
  • Article number
    6084812
  • Gross weight, approx. m
    28.0 kg
  • Net weight, approx. m
    26 kg
  • Overall length L
    333.0 mm
  • Height without packaging H
    608 mm
  • Colour
    silver/black
  • Packaging property
    Transport packaging
  • Packaging type
    Cardboard box
  • Number per layer
    1
  • Width without packaging L
    247.0 mm
  • Minimum order quantity
    1
  • Pieces per pallet
    8

Tender text

Fully submersible drainage pump for transportable wet well installation for pumping wastewater and sewage that is free of faeces (within the meaning of EN 12050-2). Hydraulics housing and impeller made of composite, motor housing made of stainless steel. Surface-cooled motor in three-phase current version with sealing chamber and thermal motor monitoring. 10 m connection cable with fitted CEE plug and float switch for automatic level control. The sealing on the fluid and on the motor side is performed by two bidirectional mechanical seals.

Operating data
  • Fluid media
    Water
Product data
  • Free ball passage of the hydraulics
    10 mm
  • Maximum operating pressure PN
    3 bar
  • Max. immersion depth
    7.00 m
  • Min. fluid temperature T
    3 °C
  • Max. fluid temperature T
    40 °C
Motor data
  • Mains connection
    3~400 V, 50 Hz
  • Voltage tolerance
    ±10 % %
  • Power factor cos φ
    0.84
  • Rated power P2
    2.50 kW
  • Power consumption P1 max
    3200 W
  • Rated current IN
    5.50 A
  • Starting current I
    31 A
  • Activation type
    Direct online (DOL)
  • Max. switching frequency t
    30 1/h
  • Insulation class
    F
  • Protection class
    IP68
  • Operating mode (immersed)
    S1
  • Operating mode (non-immersed)
    S2-15 min
Cable
  • Connection cable length
    10.0 m
  • Cable type
    H07RN-F
  • Cable cross-section
    6G1 mm²
Equipment/function
  • Explosion protection type
    no
  • Motor protection
    Bimetallic
Materials
  • Pump housing
    PP-GF30
  • Impeller
    PP-GF30
  • Shaft
    1.4401, X5CrNiMo17-12-2
  • Gasket material
    NBR
  • Motor housing
    1.4301, X5CrNi18-10
Installation dimensions
  • Pipe connection on the suction side
    -
  • Pipe connection on the pressure side
    G 2
Information for order placements
  • Brand
    Wilo
  • Product description
    Padus UNI M05/T25-540/A
  • Net weight, approx. m
    26 kg
  • Article number
    6084812

Downloads

Wilo-Padus UNI

Article Number 6084248
Edition 2019-02
Version number 02
Page format 209.9 x 297.0 mm
Number of pages 720

PDF (11 MB)

Download

REACH Regulation

Edition 2018-10
Page format 209.9 x 296.7 mm
Number of pages 4

PDF (581 kB)

Download

PDF: Padus UNI M05/T25-540/A

Configure

Page selection

Format selection

Optional information

You can enter any personal information that you want to be displayed in the header.

Download