Wilo-Stratos MAXO-Z
Superior intelligence, unparalleled quality.
Superior intelligence, unparalleled quality.
The Wilo-Stratos MAXO-Z has specifically been developed for drinking water applications and combines the innovative characteristics of the Wilo-Stratos MAXO with a stainless steel housing. The durable and hygienic material sets it apart from other domestic hot water circulators on the market.
Recommended services
Your advantages
- Intuitive operation by means of application-guided settings with the Setting assistant plus the combination of a new display and operating button using Green Button Technology.
- Highest standard of drinking water hygiene and energy efficiency with the new, innovative, intelligent T-const. control function.
- Optimum hygiene promotion through thermal disinfection detection.
- Latest communication interfaces (e.g. Bluetooth) for connection to mobile devices and direct pump networking for multiple pump control via Wilo Net.
Environmentally friendly features
- Combination of optimised and innovative control modes provides maximum energy efficiency
- Sustainable and carbon-neutral production and processes in our European factories
- Full transparency of the pump's operating status via remote access to save resources compared to on-site assessments
Design
Smart glandless circulator with oval flange and round flange connection and EC motor with integrated electronic power adjustment
Application
Domestic hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems
Max. Flow: 240 GPM
Max. Head: 40 feet
Equipment/function
Field of application
The pump facilitates an operation with highest system efficiency via precise setting of the control mode for the system-specific application (e.g. radiator, underfloor heating, ceiling cooling).
Heating
- Radiator
- Underfloor heating
- Ceiling heating
- Fan heater
- Hydraulic shunt
- Heat exchanger
Cooling
- Ceiling cooling
- Underfloor cooling
- Air-conditioning devices
- Hydraulic shunt
- Heat exchanger
Heating and cooling combined
- Automatic switchover
The following control modes are available depending on the selected application:
Control modes
- Constant speed (control mode)
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Dynamic Adapt plus for continuous (dynamic) adjustment of the delivery rate to the current requirement
- T-const. for constant temperature regulation
- ΔT for differential temperature control
- Constant Q for constant volume flow control
- Multi-Flow Adaptation: Total volume flow determination through the feeder pump for the needs-based supply of secondary pumps in the heating circuit distributors
- User-defined PID controller
Optional functions
- Q-limitmax. for limiting the maximum volume flow
- Q-limitmin. for limiting the minimum volume flow
- No-Flow Stop (zero-flow-deactivation)
- Automatic setback operation
- Index circuit evaluator (Δp-c control with external actual value sensor)
- Thermal disinfection detection
- Variable pitch of Δp-v pump curve
Manual settings
- Selection of the field of application using the Setup Guide
- Setting the related operating parameters
- Nominal duty point: direct input of calculated duty point at Δp-v
- Status display
- Setting and resetting the energy meters (heating and cooling)
- Pump venting function
- Key lock for disabling the settings
- Function for resetting the factory settings or the saved restoration points (parameter sets)
- Parameterising the analogue inputs
- Parameterising the binary inputs
- Parameterising the relay outputs
Automatic functions
- Power adjustment according to requirements for energy-efficient operation depending on the operating mode
- Setback operation
- Deactivation at zero flow (No-Flow Stop)
- Soft start
- Automatic troubleshooting routines (e.g. deblocking function)
- Switchover heating/cooling mode
- Full motor protection with integrated trip electronics
External control inputs and their functions
2 x analogue inputs:
- Signal types: 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA, PT1000
- Applications: Remote adjustment of the setpoints in every control mode (except Multi-Flow Adaptation), sensor inputs for temperature, differential pressure or free sensor in user-defined PID-operating mode
2 x digital inputs:
- For potential-free control outputs or switch
- Parametrizable functions:
- Ext. Off
- Ext. Min
- Ext. Max
- MANUAL (BMS-OFF)
- Key lock
- Switchover between heating/cooling mode
Wilo Net for dual pump management of 2 single pumps, communication of several pumps with each other and pump-remote adjustment via gateway
Signal and display functions
- Display status operation display:
- Setpoint
- Actual delivery head
- Actual volume flow
- Power consumption
- Electric consumption
- Temperatures
- Status display LED: Faultless operation (green LED), pump communication (blue LED)
- Display status of display fault (display red):
- Error codes and error description in full text
- Remedial measures
- Display status of display warning (display yellow):
- Warning codes and description of the warning in full text
- Remedial measures
- Display status process indicator display (display blue):
- Pump venting
- Update procedure
- Display BMS communication (display blue):
- Summary of the active BMS parameters (baud rate, address,...)
- Collective fault signal SSM (potential-free changeover contact)
- Collective run signal SBM (potential-free normally open contact)
Data exchange
- Bluetooth interface for wireless data exchange and remote operation of the pump using a smartphone or tablet.
- Serial digital interface Modbus RTU for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module Modbus RTU).
- Serial digital interface BACnet MS/TP for connecting building automation (BA) via RS485 bus system (possible with Wilo-CIF module BACnet MS/TP).
Equipment
- Various integrated communication interfaces and optionally usable CIF module plug-in position
- 5 cable inlets for connecting the communication interfaces
- Bluetooth interface
- High resolution graphic display with green button and 2 additional buttons
- User-friendly terminal room
- Integrated temperature sensor in the pump housing
- Quick electrical connection with optimized Wilo-Connector including a ½ NPT connection adapter for the power supply
Typekey
Example: | Stratos MAXO-D 3x3-40 |
Stratos MAXO | Pump designation |
Single Pump | |
-D | Double Pump |
-Z | Single pump for drinking water circulation system |
3 | Flange Connection in inches |
Continuously variable setpoint height 3 – 40 ft | |
3-40 | Minimum delivery head 3.3 ft |
Technical data
- Permissible temperature range
- Drinking water up to 3.57 mmol/l: 32 °F (0 °C) to 176 °F (+80 °C)
- Heating water: 14 °F (-10 °C) to 230 °F (+110 °C)
- Mains connection:
- 1~115 V, 50/60 Hz (depending on type),
- 1~230 V-240 V, 50/60 Hz
- Enclosure: Type 2
- Flange connection: 1.25, 2 and 3 inch
- Max. operating pressure: 145 psi
- Insulation class: F
- Emitted interference in acc. with: EN 61800-3:2004+A1:2012 / residential environment (C1)
- Interference resistance in acc. with: EN 61800-3:2004+A1:2012 / industrial environment (C2)
Materials
- Pump housing made of stainless steel
- Thermal insulation: polypropylene
- Impeller: Plastic
- Shaft: Stainless steel
- Bearing: carbon
Construction
- Smart glandless circulator with EC motor and integrated electronic power adjustment
- Green Button Technology and graphic display
- Motor protection with trip electronics
- Plug connection for functional extension with optional CIF module for building automation (BA)
- Impeller with three-dimensionally curved blades and plastic sealing tube made of carbon fibre composite material
Scope of delivery
- Pump
- Optimized Wilo-Connector with ½ NPT connection adapter
- 5x threaded cable gland M16 x 1.5
- Gaskets for 1.25 and 2 inch flange connection
- Installation and operating instructions
Options
NO VALUE
Accessories
- PT 1000 (B) pipe contact sensor (for domestic hot water)
- PT 1000 (AA) sensor for installation in immersion well
- Differential pressure sensor
- Wilo CIF modules: Modbus RTU, BACnet MS/TP
Installation and operating instructions
General overview
Release notes Software
Accessories sheet
Reference sheet
Product description | Pump connection | Mains connection | Gross weight, approx. m | Pieces per pallet | Maximum operating pressure | Article number | |
---|---|---|---|---|---|---|---|
Stratos-MAXO Z 2x3-35 145PSI | 2.00" | 1~230-240 V, 50/60 Hz | 0.85 lb | 8 | 145 psi | 2164625 | |
Stratos MAXO-Z 1.25x3-25 145PSI1~115/230 | 1.25" | 1~115, 230-240 V, 50/60 Hz | 0.48 lb | 8 | 145 psi | 2164623 | |
Stratos MAXO-Z 1.25x3-35 145PSI1~115/230 | 1.25" | 1~115, 230-240 V, 50/60 Hz | 0.72 lb | 8 | 145 psi | 2164624 | |
Stratos MAXO-Z 3x3-40 145PSI | 3" ANSI Class 125 | 1~230-240 V, 50/60 Hz | 1.41 lb | 8 | 145 psi | 2164626 |