Hydraulic data
Max. operating pressure p 145.036839357197 psi
Maximum operating pressure 145 psi
Min. fluid temperature Tmin 15 °F
Max. fluid temperature Tmax 250 °F
Max. ambient temperature Tmax 104 °F
Motor data
Mains connection 1~115/208-230 V, 60 Hz
Number of poles 4
Rated power P2 0.50 hp
Rated current IN 4.2 A
Insulation class F
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Mechanical seal Q1Q1X4GG
Pump housing material EN-GJL-250 (ASTM A48)
Impeller PPE+PS-GF30
Shaft AISI 316L
Installation dimensions
Pipe connection on the suction side DNs 2" ANSI Class 125
Pipe connection on the discharge side DNd 2" ANSI Class 125
Port-to-port length in inch L0 14.02 in (")
Product data
Brand Wilo
Product description IPL 2 18/125-4 1-115/230V
Article number 2705369
EAN number -
Date of sales availability 2010-01-01
Dimension, weight
Length L 14.02 in (")
Length L 356 mm
Height H 21.06 in (")
Height H 535 mm
Width W 9.76 in (")
Width W 248 mm
Net weight, approx. m -
Net weight, approx. m 30.1 kg
Documents

Installation and operating instructions

Wilo-IPL IOM

Article Number 2060099
Edition 05/06
Number of pages 44
Language bg, cs, da, de, el, en, et, fi, hr, hu, it, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (2 MB)

Wilo-IPL

Article Number 2060099
Edition 05/06
Number of pages 17
Language en
PDF (649 KB)

Certification booklet

Wilo-VeroLine-IP-E, Wilo-VeroTwin-DP-E, Wilo-VeroLine-IPL, Wilo-VeroTwin-DPL, Wilo-VeroLine-IPL-N, Wilo-VeroTwin-DPL-N, Wilo-VeroLine-IPH, Wilo-BM/BM-B/BM-S, Wilo-VeroLine-IP-Z

Article Number 2216679
Edition 2022-11
Number of pages 60
Language language neutral
PDF (22 MB)
BIM/CAD

3D_STEP

2705369, PUMP IPL2-18/125-4,0.5HP,1PH

Language language neutral
STP (943 KB)