Technical data
Hydraulic data
Minimum efficiency index (MEI) ≥0,4
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Drive
Mains connection 3~380 V, 50/60 Hz
Number of poles 4
Motor efficiency class IE4
Power consumption P1 max 8,50 kW
Rated power P2 7,5 kW
Max current Imax 13,7 A
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal Q1Q1X4GG
Lantern 5.1301/EN-GJL-250 KTL-coated
Approved liquids (other liquids upon request)
Heating water (as per VDI 2035) yes
Heat carrier oil Special version at additional charge
Cooling and cold water circulation systems yes
Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) yes
Installation dimensions
Port-to-port length L0 700 mm
Pipe connection on the suction side DNs DN 150
Pipe connection on the discharge side DNd DN 150

CronoLine-IL-E 150/200-7,5/4-R1

L1, L2, L3: Mains connection: 3~440 V ±10%, 50/60 Hz; 3~400 V ±10%, 50/60 Hz; 3~380 V -5%/+10%, 50/60 Hz
PE: Protective conductor connection
DDG: Connection for differential pressure sensor
In1 (1): Actual value input 0-10 V/0-20 mA; 2-10 V/4-20 mA
GND (2): Ground connection for In1 and In2
+ 24 V (3): DC voltage output for an external consumer/sensor. Max load 60 mA
In2: Setpoint input 0-10 V/0-20 mA; 2-10 V/4-20 mA
MP: Multi-pump, interface for dual pump management
Ext. off: Control input “Overriding Off”The pump can be switched on or off via an external, potential-free contact (24 V DC/10 mA).
SBM:* Potential-free collective run signal (changeover contact according to VDI 3814)
SSM:* Potential-free collective fault signal (changeover contact according to VDI 3814)
aux: External pump cycling (only with dual pump operation). Pump cycling can be performed using an external, potential-free contact (24 VDC/10 mA)
DIP switch: 1: Switchover between operation (O) and service mode (S)2: Activate/deactivate the menu for access disable
Optional: IF-Modules for connection to the building automation

* Load capacity of contacts for SBM and SSM:

min.: 12 V DC/10 mA

max.: 250 V AC/1 A

Airborne sound data sheet

Airborne sound power LW,A
Octave band centre frequency in Hz Level in dB(A), ref. 20µPa
63 33,7
125 51,3
250 61,8
500 68,2
1000 78,2
2000 68
4000 70
8000 62,5
Airborne sound-power level (total) Lw 79,7 db(A)
Airborne sound pressure Lp,A,1m
Octave band centre frequency in Hz Level in dB(A), ref. 1pW
63 19,7
125 37,3
250 47,8
500 54,2
1000 64,2
2000 54
4000 56
8000 48,5
Airborne sound-pressure level (total) Lp 65,7 db(A)
The acoustic values given are based on measurements and in some cases on calculations and may deviate by up to 3 dB.
Product data
Brand Wilo
Product description CronoLine IL-E 150/200-7,5/4-R1-S1
Article number 2193267
EAN number 4048482808703
Colour Green
Minimum order quantity 1
Date of sales availability 2021-08-27
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1200 mm
Length L 972 mm
Height with packaging 1200 mm
Height H 693 mm
Width with packaging 800 mm
Width W 473 mm
Gross weight, approx. m 263 kg
Net weight, approx. m 213 kg
Tender text

Glanded centrifugal pump with in-line design for pipe installation with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v).

Design:

  • Single-stage low-pressure centrifugal pump
  • Spiral housing in in-line design (suction and pressure ports with the same flanges in one line), flanges PN 16 – drilled acc. to EN 1092-2
  • Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
  • Pump housing and motor flange with cataphoretic coating as standard.
  • Mechanical seal S1 recommended for water-glycol mixtures with glycol proportions up to max. 50% by volume and a fluid temperature of -20 °C up to max. +110 °C and also for oil proportions in the water-glycol mixture.

Accessories:

  • Mounting brackets for fixing to the foundation
  • IR-Monitor
  • IR-Stick
  • IF module PLR
  • IF module LON
  • IF module Modbus
  • IF module BACnet
  • IF module CAN
  • Control systems VR-HVAC/CCe-HVAC/SCe-HVAC
  • Differential pressure sensor (DDG) sets 0-10 V for pumps in version ...-R1

Standard equipment:

  • One-button manual operation level for:
    • Pump On/Off
    • Setpoint and speed adjustment
    • Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
    • Selection of operating mode in twin-head pump operation (main/standby operation, parallel operation)
    • Configuration of operating parameters
    • Fault acknowledgement
  • Pump display for indication of:
    • Control mode
    • Setpoint (e.g. differential pressure or speed)
    • Error and warning messages
    • Actual values (e.g. power consumption, actual value of the sensor)
    • Operating data (e.g. operating hours, energy consumption)
    • Status data (e.g. status of SSM and SBM relay)
    • Device data (e.g. pump name)

Additional functions:

  • Interfaces: Control input "Overriding Off", "External pump cycling" (effective only in twin-head pump operation), analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for constant speed (DDC) or for remote setpoint adjustment, analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal of the pressure sensor, infrared interface for wireless communication with the operating and service device Wilo-IR-Stick/IR-Monitor, slot for Wilo IF modules for connecting to the building automation, configurable, potential-free fault and operating/ready message, interface for twin-head pump communication
  • Three-phase AC motor with frequency converter
  • Integrated dual pump management
  • Adjustable time interval for pump cycling (in twin-head pump operation)
  • Integrated full motor protection
  • Different operating modes for heating (HV) or air-conditioning (AC) applications
  • Access disable
  • Different operation levels: Standard/service
Operating data
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Minimum efficiency index (MEI) ≥0,4
Drive
Mains connection
  • 3~380 V, 50/60 Hz
  • 3~400 V, 50/60 Hz
  • 3~440 V, 50/60 Hz
Motor efficiency class IE4
Power consumption P1 max 8500 W
Rated power P2 7,5 kW
Max current Imax 13,7 A
Max. speed nmax 1480 1/min
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal Q1Q1X4GG
Lantern 5.1301/EN-GJL-250 KTL-coated
Installation dimensions
Pipe connection on the suction side DNs DN 150
Pipe connection on the discharge side DNd DN 150
Port-to-port length L0 700 mm
Ordering information
Brand Wilo
Product description CronoLine IL-E 150/200-7,5/4-R1-S1
Net weight, approx. m 213 kg
Article number 2193267
Documents

Installation and operating instructions

Wilo-CronoLine-IL-E (5,5-7,5 kW), Wilo-CronoTwin-DL-E (5,5-7,5 kW)

Article Number 2160196
Edition 2022-08
Number of pages 260
Language de, en, fr, nl
PDF (27 MB)

Consulting guide

Glanded pumps, single-stage, single-volute

Edition 2021-12
Number of pages 24
Language en
PDF (7 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (287 KB)
Accessory

Continuous, infinitely variable control, differential pressure-sensitive CCe-HVAC system (27)

Continuous, infinitely variable control, temperature-dependent CCe-HVAC system (20)

Continuous, infinitely variable control, differential pressure-sensitive SCe-HVAC system (23)

Continuous, infinitely variable control, temperature-dependent SCe-HVAC system (14)

Wall fixation/installation on a base (1)

Mounting bracket kit
Mounting bracket kit
Mounting bracket F 3-18 SET
    

Mounting brackets for the installation on a base of in-line and monobloc pumps. Comprised of several angle brackets (number dependent on the pump type), intended for the screwed connection with the screw-on bases or feet of the pump. The angle brackets ensure secure fastening of the pump to the foundation. Including fixation material.

Notice

The mounting brackets / angle brackets must be lined by the dimension specified for the following pump types:

  • BL 65/270-5.5/4, BL 80/250-5.5/4, BL/BL-E 80/250-7.5/4: 30 mm
  • all types BL 100/..., BL 125/220..., BL/BL-E 125/260..., BL/BL-E 125/270...: 20 mm
  • all types BL 125/190..., BL 125/200..., BL 125/250...: 40 mm

Scope of delivery

  • Screws
  • Angle brackets
  • Screw stays
  • Nuts

Pump control/accessories (21)

Pump control/Comfort control system (6)

Pump control/Smart control system (4)

Pump control/interface module (6)

Differential pressure detection (9)

Operating/service units (1)