Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
CronoLine IL-E 40/210-11/2 | Wilo

CronoLine IL-E 40/210-11/2

Article number : 2231556
Technical data
Hydraulic data
Minimum efficiency index (MEI) ≥0,4
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Drive
Mains connection 3~400 V, 50/60 Hz
Number of poles 2
Motor efficiency class IE4
Power consumption P1 max 11,30 kW
Rated power P2 11 kW
Max current Imax 17,6 A
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal AQ1EGG
Lantern 5.1301/EN-GJL-250 KTL-coated
Approved liquids (other liquids upon request)
Heating water (as per VDI 2035) yes
Heat carrier oil Special version at additional charge
Cooling and cold water circulation systems yes
Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) yes
Installation dimensions
Port-to-port length L0 390 mm
Pipe connection on the suction side DNs DN 40
Pipe connection on the discharge side DNd DN 40

IL-E 40/210-11/2

Product data
Brand Wilo
Product description CronoLine IL-E 40/210-11/2
Article number 2231556
EAN number 4062679353951
Colour Green
Minimum order quantity 1
Date of sales availability 2023-10-15
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1200 mm
Length L 813 mm
Height with packaging 1200 mm
Height H 631 mm
Width with packaging 800 mm
Width W 429 mm
Gross weight, approx. m 220 kg
Net weight, approx. m 173 kg
Tender text

Glanded centrifugal pump with in-line design for pipe installation with built-in frequency converter for electronic control for constant or variable differential pressure (dp-c/dp-v).

Design:

  • Single-stage low-pressure centrifugal pump
  • Spiral housing in in-line design (suction and discharge ports with the same flanges in one line), flanges PN 16 – drilled acc. to EN 1092-2
  • Pressure measuring connections (R 1/8) for mounted differential pressure sensor (version ...-R1 without differential pressure sensor)
  • Pump housing and motor flange with cataphoretic coating as standard.
  • Mechanical seal for pumping water up to Tmax. = +140 °C. A glycol admixture of 20 % to +40 % by volume is permitted up to T ≤ +40 °C. An alternative mechanical seal must be provided in water-glycol mixtures with glycol proportions > 40 % up to max. 50 % by volume and a fluid temperature of > +40 °C up to max. +120 °C or fluids other than water. When using water-glycol mixtures, the use of an S1 variant with a corresponding mechanical seal is generally recommended.

Accessories:

  • Mounting brackets for fixing to the foundation
  • IR-Stick
  • IF module PLR
  • IF module LON
  • IF module Modbus
  • IF module BACnet
  • IF module CAN
  • Control system VR-HVAC
  • Control system CCe-HVAC
  • Control system SCe-HVAC
  • Differential pressure sensor (DDG)

Standard equipment:

  • One-button manual operation level for:
    • Pump On/Off
    • Setpoint and speed adjustment
    • Selecting the control mode: Δp-c (constant differential pressure), Δp-v (variable differential pressure), PID controller, n-constant (constant speed)
    • Selection of operating mode in dual-pump operation (main/standby operation, parallel operation)
    • Configuration of operating parameters
    • Fault acknowledgement
  • Pump display for indication of:
    • Control mode
    • Setpoint (e.g. differential pressure or speed)
    • Error and warning messages
    • Actual values (e.g. power consumption, actual value of the sensor)
    • Operating data (e.g. operating hours, energy consumption)
    • Status data (e.g. status of SSM and SBM relay)
    • Device data (e.g. pump name)

Additional functions

  • 1x “Overriding OFF” control input
  • 1x “External pump cycling” (effective only in twin-head pump operation)
  • 1x Analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for constant speed (DDC) or remote setpoint adjustment,
  • 1x Analogue input 0–10 V, 2–10 V, 0–20 mA, 4–20 mA for actual value signal from pressure sensor
  • IR interface for wireless communication with Wilo-IR-Stick operating and service device,
  • Slot for Wilo IF modules for connection to the building automation system,
  • Configurable, potential-free fault and operating/standby signal
  • 1x Interface to dual-pump communication
  • Three-phase AC motor with frequency converter
  • Integrated dual-pump management
  • Adjustable time interval for pump cycling (in dual-pump operation)
  • Integrated full motor protection
  • Different operating modes for heating (HV) or air-conditioning (AC) applications
  • Access disable
  • Different operation levels: Standard/service
Operating data
Min. fluid temperature Tmin -20 °C
Max. fluid temperature Tmax 140 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Maximum operating pressure PN 16 bar
Note on dimensioning 16 bar to 120 °C, 13 bar to 140 °C
Minimum efficiency index (MEI) ≥0,4
Drive
Mains connection 3~400 V, 50/60 Hz
Motor efficiency class IE4
Power consumption P1 max 11300 W
Rated power P2 11 kW
Max current Imax 17,6 A
Max. speed nmax 2960 1/min
Emitted interference EN 61800-3
Interference resistance EN 61800-3
Insulation class F
Protection class motor IP55
Motor protection PTC integrated
Materials
Pump housing 5.1301/EN-GJL-250 KTL-coated
Impeller Grey cast iron
Shaft Stainless steel
Shaft seal AQ1EGG
Lantern 5.1301/EN-GJL-250 KTL-coated
Installation dimensions
Pipe connection on the suction side DNs DN 40
Pipe connection on the discharge side DNd DN 40
Port-to-port length L0 390 mm
Ordering information
Brand Wilo
Product description CronoLine IL-E 40/210-11/2
Net weight, approx. m 173 kg
Article number 2231556
Documents

Installation and operating instructions

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234255
Edition 2024-02
Number of pages 88
Language en
PDF (13 MB)

Wilo-CronoLine-IL-E (11-22 kW), Wilo-CronoTwin-DL-E (11-22 kW), Wilo-CronoBloc-BL-E (1,5-22 kW)

Article Number 2234256
Edition 2024-02
Number of pages 328
Language de, en, fr, nl
PDF (21 MB)

Consulting guide

Glanded pumps, single-stage, single-volute

Edition 2021-12
Number of pages 24
Language en
PDF (7 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (287 KB)
BIM/CAD
Accessory

Continuous, infinitely variable control, differential pressure-sensitive CCe-HVAC system (27)

Continuous, infinitely variable control, temperature-dependent CCe-HVAC system (20)

Continuous, infinitely variable control, differential pressure-sensitive SCe-HVAC system (23)

Continuous, infinitely variable control, temperature-dependent SCe-HVAC system (14)

Pipe installation, adapter fitting (7)

Wall fixation/installation on a base (1)

Pump control/accessories (21)

Pump control/Comfort control system (6)

Pump control/Smart control system (4)

Pump control/interface module (6)

Differential pressure detection (8)

Operating/service units (1)