Suche
Kontakt
E-Mail
Katalogerstellung
Meine Favoriten
Produktvergleich
SC/SC-FC-HVAC system | Wilo
Your advantages
Wilo-SCe-HVAC system

Your advantages

  • Easy operation: Display, symbols and menu navigation analogous to the Wilo glanded pumps of the latest design
  • Easy-to-use system: System access to the service menu protected via code, error history code with up to 16 individual messages
  • Reliable system: Permanent display of pumps and system status as well as the actual value present in the display
  • SBM and SSM as standard, other error messages/alarm signals can optionally be output via relay or via other communication tools (e.g., bus systems)
  • Advanced settings: 2 adjustable setpoints, remote setpoint adjustment possible
  • Communication capability: Connectible bus systems: BACnet, Modbus RTU (RS 232) (LON connectible via optional module)
Series description

Design

Digitally controlled, variable Smart control systems for driving glandless and glanded pumps of all makes and single and multi-pump systems. SC version: Control of fixed speed pumps via contactors (cascade connection). SC-FC version: Control of fixed speed pumps via contactors (cascade connection), but control of a pump via frequency converter as a base-load pump, control of the peak-load pumps in cascade connection

Application

For continuous power adjustment to the variable operating states of single, twin-head or multi-pump systems (up to 4 pumps). Controlling depends on the differential pressure Δp, feed/return temperature (±T) or differential temperature (ΔT), including the free adjustment of the duty point by means of preadjustment of the full-load pump output.

Documents

Installation and operating instructions

Wilo-Control SC-HVAC (SC, SC-FC, SCe)

Article Number 2542066
Edition 2014 02
Number of pages 57
Language en
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)

CE

CE 3335004-02

Number of pages 4
Language language neutral
PDF (336 KB)

CE 2117792-07

Number of pages 6
Language language neutral
PDF (213 KB)
Product selection
Product description Max. number of controllable pumps Max. rated current per pump IArticle number Price (excl. VAT)
SC-FC-HVAC system 1x1,6A-FC-WM (direct starting)
1
1.6 A
2545426
EUR 6,262.-
SC-FC-HVAC system 1x2,4A-FC-WM (direct starting)
1
2.4 A
2545430
EUR 6,277.-
SC-FC-HVAC system 1x4A-FC-WM (direct starting)
1
4 A
2545434
EUR 6,380.-
SC-FC-HVAC system 1x6,3A-FC-WM (direct starting)
1
6.3 A
2545438
on request
SC-FC-HVAC system 1x10A-FC-WM (direct starting)
1
10 A
2545442
on request
SC-FC-HVAC system 1x12A-FC-BM (direct starting)
1
12 A
2545446
on request
SC-FC-HVAC system 1x13A-FC-BM (star-delta-starting)
1
13 A
2545466
on request
SC-FC-HVAC system 1x16A-FC-BM (direct starting)
1
16 A
2545450
on request
SC-FC-HVAC system 1x16A-FC-BM (star-delta-starting)
1
16 A
2545470
on request
SC-FC-HVAC system 1x19A-FC-BM (star-delta-starting)
1
19 A
2545474
on request
SC-FC-HVAC system 1x20A-FC-BM (direct starting)
1
20 A
2545454
on request
SC-FC-HVAC system 1x24A-FC-BM (direct starting)
1
24 A
2545458
on request
SC-FC-HVAC system 1x24A-FC-BM (star-delta-starting)
1
24 A
2545478
on request
SC-FC-HVAC system 1x32A-FC-BM (direct starting)
1
32 A
2545462
on request
SC-FC-HVAC system 1x32A-FC-BM (star-delta-starting)
1
32 A
2545482
on request
SC-FC-HVAC system 1x37,5A-FC-BM (star-delta-starting)
1
37.5 A
2545486
on request
SC-FC-HVAC system 1x43A-FC-BM (star-delta-starting)
1
43 A
2545490
on request
SC-FC-HVAC system 2x1,6A-FC-WM (direct starting)
2
1.6 A
2545427
EUR 6,654.-
SC-FC-HVAC system 2x2,4A-FC-WM (direct starting)
2
2.4 A
2545431
EUR 6,666.-
SC-FC-HVAC system 2x4A-FC-WM (direct starting)
2
4 A
2545435
EUR 6,790.-
SC-FC-HVAC system 2x6,3A-FC-WM (direct starting)
2
6.3 A
2545439
on request
SC-FC-HVAC system 2x10A-FC-WM (direct starting)
2
10 A
2545443
on request
SC-FC-HVAC system 2x12A-FC-BM (direct starting)
2
12 A
2545447
on request
SC-FC-HVAC system 2x13A-FC-BM (star-delta-starting)
2
13 A
2545467
on request
SC-FC-HVAC system 2x16A-FC-BM (direct starting)
2
16 A
2545451
on request
SC-FC-HVAC system 2x16A-FC-BM (star-delta-starting)
2
16 A
2545471
on request
SC-FC-HVAC system 2x19A-FC-BM (star-delta-starting)
2
19 A
2545475
on request
SC-FC-HVAC system 2x20A-FC-BM (direct starting)
2
20 A
2545455
on request
SC-FC-HVAC system 2x24A-FC-BM (direct starting)
2
24 A
2545459
on request
SC-FC-HVAC system 2x24A-FC-BM (star-delta-starting)
2
24 A
2545479
on request
SC-FC-HVAC system 2x32A-FC-BM (direct starting)
2
32 A
2545463
on request
SC-FC-HVAC system 2x32A-FC-BM (star-delta-starting)
2
32 A
2545483
on request
SC-FC-HVAC system 2x37,5A-FC-BM (star-delta-starting)
2
37.5 A
2545487
on request
SC-FC-HVAC system 2x43A-FC-BM (star-delta-starting)
2
43 A
2545491
on request
SC-FC-HVAC system 3x1,6A-FC-WM (direct starting)
3
1.6 A
2545428
EUR 7,041.-
SC-FC-HVAC system 3x2,4A-FC-WM (direct starting)
3
2.4 A
2545432
EUR 7,068.-
SC-FC-HVAC system 3x4A-FC-WM (direct starting)
3
4 A
2545436
EUR 7,224.-
SC-FC-HVAC system 3x6,3A-FC-WM (direct starting)
3
6.3 A
2545440
on request
SC-FC-HVAC system 3x10A-FC-WM (direct starting)
3
10 A
2545444
on request
SC-FC-HVAC system 3x12A-FC-BM (direct starting)
3
12 A
2545448
on request
SC-FC-HVAC system 3x13A-FC-BM (star-delta-starting)
3
13 A
2545468
on request
SC-FC-HVAC system 3x16A-FC-BM (direct starting)
3
16 A
2545452
on request
SC-FC-HVAC system 3x16A-FC-BM (star-delta-starting)
3
16 A
2545472
on request
SC-FC-HVAC system 3x19A-FC-BM (star-delta-starting)
3
19 A
2545476
on request
SC-FC-HVAC system 3x20A-FC-BM (direct starting)
3
20 A
2545456
on request
SC-FC-HVAC system 3x24A-FC-BM (direct starting)
3
24 A
2545460
on request
SC-FC-HVAC system 3x24A-FC-BM (star-delta-starting)
3
24 A
2545480
on request
SC-FC-HVAC system 3x32A-FC-BM (direct starting)
3
32 A
2545464
on request
SC-FC-HVAC system 3x32A-FC-BM (star-delta-starting)
3
32 A
2545484
on request
SC-FC-HVAC system 3x37,5A-FC-BM (star-delta-starting)
3
37.5 A
2545488
on request