The universal single-stage centrifugal pump for many applications in heating, cooling and industrial circulation systems.

Your advantages
Atmos BST Flange

The universal single-stage centrifugal pump for many applications in heating, cooling and industrial circulation systems.

The wide range of hydraulic components and motors available for the single-stage centrifugal pump Wilo-Atmos BST enable it to be deployed for a variety of applications in air conditioning and cooling technology, water supply, pressure boosting and water treatment. It can be used to pump water as well as non-aggressive and slightly aggressive liquids, for example in a car wash, for industrial cooling systems or for irrigation in agriculture. Its hydraulic components made of stainless steel provide high resistance to corrosion and long service life. The block construction combined with the pump feet enable quick installation as well as low-vibration and quiet-running operation. The modern pump hydraulics together with the IE3 motors equipped as standard save energy.


Your advantages

  • Ultra-modern pump hydraulics and the IE3 motor save energy
  • Various impeller materials, multiple motor options and a wide range of mechanical seals enable universal deployment in many different applications
  • Block construction and pump feet enable easy installation
  • Hydraulic components made of stainless steel provide high resistance to corrosion and long service life
Series description
Wilo-Atmos BST

Design

Glanded pump in monobloc design with flange or threaded connection

Application

For pumping heating water (in accordance with VDI 2035), water-glycol mixtures, cooling water and chilled water without abrasive substances in heating, chilled water and cooling water systems.

Typekey

Beispiel

Atmos BST 32/160-1,1/2-V4

Atmos

Product Family

BST (Block Stamped)

Series

32

Nominal diameter DN of pressure port in mm

160

Nominal diameter of impeller in mm

1,1

Rated Power P2 in kW

2

Number of Poles

-V1

3~230/400 V, 50Hz

-V2

3~400/690 V, 50Hz

-V4

1~230 V, 50 Hz

-H12

Pump housing 1.4401

Technical data

  • Permissible temperature range of -20 °C to +120 °C
  • Mains connection 1~230 V, 3~400 V, 50 Hz (others on request)
  • IP rating IP55
  • Nominal diameter DN 25 to DN 80
  • Max. operating pressure 10 bar

Materials

  • Pump housing: 1.4301, 1.4401
  • Impeller: 1.4301, 1.4401
  • Pump shaft: 1.4301, 1.4401
  • Mechanical seal: B3Q1EF, B3Q1EG; other mechanical seals on request

Construction

Single-stage low-pressure centrifugal pump in monobloc design, with axial suction port and radially arranged pressure port with

  • Mechanical seal
  • Flange connection with pressure measuring connection R 1/8
  • IEC standard motor

Scope of delivery

  • Pump
  • Installation and operating instructions
Documents

Installation and operating instructions

Wilo-Atmos BST

Article Number 9221306
Edition 2023-07
Number of pages 288
Language de, en, es, fr, hu, it, ko, pl, pt, sv, tr
PDF (7 MB)

Wilo-Atmos BST

Article Number 9221306
Edition 2023-07
Number of pages 32
Language en
PDF (5 MB)

Certification booklet

Wilo-Atmos BST 25, Wilo-Atmos BST 32 - 80

Article Number 9223929
Edition 2023-07
Number of pages 24
Language language neutral
PDF (6 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)

Flyer

Product flyer Wilo-Atmos BST

Number of pages 2
Language en
PDF (4 MB)
Product selection
Number of results: 134
Nominal flange diameter
Maximum operating pressure PN
Rated power P2
0.55 … 37 kW
[133]
Number of poles
Product description Number of poles MEI Nominal flange diameter Rated power P2Gross weight, approx. mArticle number Price (excl. VAT)
Atmos BST 25/130-0.55/2-H12-V1
2
≥0.4
G 1
0.55 kW
8.8 kg
9187115
EUR 438.-
Atmos BST 25/130-0.55/2-H12-V4
2
≥0.4
G 1
0.55 kW
9.5 kg
9187114
EUR 428.-
Atmos BST 25/130-0.55/2-V1
2
≥0.4
G 1
0.55 kW
8.8 kg
9187030
EUR 373.-
Atmos BST 25/130-0.55/2-V4
2
≥0.4
G 1
0.55 kW
9.5 kg
9187029
EUR 366.-
Atmos BST 25/130-0.75/2-H12-V1
2
≥0.4
G 1
0.75 kW
9.5 kg
9187121
EUR 462.-
Atmos BST 25/130-0.75/2-H12-V4
2
≥0.4
G 1
0.75 kW
10.5 kg
9187120
EUR 452.-
Atmos BST 25/130-0.75/2-V1
2
≥0.4
G 1
0.75 kW
9.5 kg
9187036
EUR 396.-
Atmos BST 25/130-0.75/2-V4
2
≥0.4
G 1
0.75 kW
10.5 kg
9187035
EUR 386.-
Atmos BST 25/130-1.1/2-H12-V1
2
≥0.4
G 1
1.1 kW
11.8 kg
9187127
EUR 507.-
Atmos BST 25/130-1.1/2-H12-V4
2
≥0.4
G 1
1.1 kW
13.7 kg
9187126
EUR 530.-
Atmos BST 25/130-1.1/2-V1
2
≥0.4
G 1
1.1 kW
11.8 kg
9187042
EUR 438.-
Atmos BST 25/130-1.1/2-V4
2
≥0.4
G 1
1.1 kW
13.7 kg
9187041
-
Atmos BST 25/160-0.75/2-H12-V1
2
≥0.4
G 1
0.75 kW
9.1 kg
9187117
EUR 462.-
Atmos BST 25/160-0.75/2-H12-V4
2
≥0.4
G 1
0.75 kW
10.6 kg
9187116
EUR 452.-
Atmos BST 25/160-0.75/2-V1
2
≥0.4
G 1
0.75 kW
9.1 kg
9187032
EUR 395.-
Atmos BST 25/160-0.75/2-V4
2
≥0.4
G 1
0.75 kW
10.6 kg
9187031
EUR 385.-
Atmos BST 25/160-1.1/2-H12-V1
2
≥0.4
G 1
1.1 kW
10.6 kg
9187123
EUR 507.-
Atmos BST 25/160-1.1/2-H12-V4
2
≥0.4
G 1
1.1 kW
13.8 kg
9187122
EUR 530.-
Atmos BST 25/160-1.1/2-V1
2
≥0.4
G 1
1.1 kW
10.6 kg
9187038
EUR 438.-
Atmos BST 25/160-1.1/2-V4
2
≥0.4
G 1
1.1 kW
13.8 kg
9187037
EUR 459.-
Atmos BST 25/160-1.85/2-H12-V1
2
≥0.4
G 1
1.85 kW
14.8 kg
9187129
EUR 659.-
Atmos BST 25/160-1.85/2-H12-V4
2
≥0.4
G 1
1.85 kW
16 kg
9187128
EUR 595.-
Atmos BST 25/160-1.85/2-V1
2
≥0.4
G 1
1.85 kW
14.8 kg
9187044
EUR 586.-
Atmos BST 25/160-1.85/2-V4
2
≥0.4
G 1
1.85 kW
16 kg
9187043
EUR 524.-
Atmos BST 25/160-1/2-H12-V1
2
≥0.4
G 1
1 kW
10.7 kg
9187119
EUR 477.-
Atmos BST 25/160-1/2-H12-V4
2
≥0.4
G 1
1 kW
11.5 kg
9187118
EUR 471.-
Atmos BST 25/160-1/2-V1
2
≥0.4
G 1
1 kW
10.7 kg
9187034
EUR 410.-
Atmos BST 25/160-1/2-V4
2
≥0.4
G 1
1 kW
11.5 kg
9187033
EUR 403.-
Atmos BST 25/180-1.85/2-H12-V1
2
≥0.4
G 1
1.85 kW
15.5 kg
9187125
EUR 679.-
Atmos BST 25/180-1.85/2-H12-V4
2
≥0.4
G 1
1.85 kW
17.2 kg
9187124
EUR 613.-
Atmos BST 25/180-1.85/2-V1
2
≥0.4
G 1
1.85 kW
15.5 kg
9187040
EUR 599.-
Atmos BST 25/180-1.85/2-V4
2
≥0.4
G 1
1.85 kW
17.2 kg
9187039
EUR 535.-
Atmos BST 25/180-2.2/2-H12-V1
2
≥0.4
G 1
2.2 kW
21.2 kg
9187131
EUR 680.-
Atmos BST 25/180-2.2/2-H12-V4
2
≥0.4
G 1
2.2 kW
22.9 kg
9187130
EUR 747.-
Atmos BST 25/180-2.2/2-V1
2
≥0.4
G 1
2.2 kW
21.2 kg
9187046
EUR 600.-
Atmos BST 25/180-2.2/2-V4
2
≥0.4
G 1
2.2 kW
22.9 kg
9187045
EUR 666.-
Atmos BST 32/160-1.1/2-H12-V1
2
≥0.4
DN 32
1.1 kW
26.5 kg
9187133
EUR 855.-
Atmos BST 32/160-1.1/2-H12-V4
2
≥0.4
DN 32
1.1 kW
26.5 kg
9187132
EUR 969.-
Atmos BST 32/160-1.1/2-V1
2
≥0.4
DN 32
1.1 kW
26.5 kg
9187048
EUR 719.-
Atmos BST 32/160-1.1/2-V4
2
≥0.4
DN 32
1.1 kW
26.5 kg
9187047
EUR 819.-
Atmos BST 32/160-1.5/2-H12-V1
2
≥0.4
DN 32
1.5 kW
25.5 kg
9187135
EUR 996.-
Atmos BST 32/160-1.5/2-H12-V4
2
≥0.4
DN 32
1.5 kW
21.7 kg
9187134
EUR 1,022.-
Atmos BST 32/160-1.5/2-V1
2
≥0.4
DN 32
1.5 kW
25.5 kg
9187050
EUR 844.-
Atmos BST 32/160-1.5/2-V4
2
≥0.4
DN 32
1.5 kW
21.7 kg
9187049
EUR 870.-
Atmos BST 32/160-2.2/2-H12-V1
2
≥0.4
DN 32
2.2 kW
31 kg
9187137
EUR 1,098.-
Atmos BST 32/160-2.2/2-H12-V4
2
≥0.4
DN 32
2.2 kW
28.5 kg
9187136
EUR 1,185.-
Atmos BST 32/160-2.2/2-V1
2
≥0.4
DN 32
2.2 kW
31 kg
9187052
EUR 946.-
Atmos BST 32/160-2.2/2-V4
2
≥0.4
DN 32
2.2 kW
28.5 kg
9187051
EUR 1,032.-
Atmos BST 32/200-3/2-H12-V1
2
≥0.4
DN 32
3 kW
38.1 kg
9187138
EUR 1,460.-
Atmos BST 32/200-3/2-V1
2
≥0.4
DN 32
3 kW
38.1 kg
9187053