Flumen EXCEL-TRE 50-3.28-4/12 E4
Hydraulic data | |
---|---|
Max. immersion depth | 20 m |
Min. fluid temperature Tmin | 3 °C |
Max. fluid temperature Tmax | 40 °C |
Min. ambient temperature Tmin | 3 °C |
Max. ambient temperature Tmax | 40 °C |
Motor data | |
---|---|
Mains connection | 3~400 V, 50 Hz |
Voltage tolerance | ±10 % |
Rated power P2 | 1.9 kW |
Power consumption P1 max | 2.25 kW |
Rated current IN | 4.65 A |
Operating mode (immersed) | S1 |
Operating mode (non-immersed) | – |
Rated speed n | 1450 1/min |
Power factor cos φ100 | 0.69 |
Number of poles | 4 |
Max. switching frequency t | 15 1/h |
Insulation class | H |
Protection class motor | IP68 |
Cable | |
---|---|
Type of connection cable | Non-detachable |
Equipment/function | |
---|---|
Explosion protection type | - |
Motor protection | Bimetall |
Motor, leakage detection | no |
Sealing chamber, leakage detection | optional |
Leakage chamber, leakage detection | no |
Materials | |
---|---|
Gasket material | FKM |
Motor housing | Grey cast iron |
WILO-Flumen EXCEL-TRE 50-3
Product data | |
---|---|
Brand | Wilo |
Product description | Flumen EXCEL-TRE 50-3.28-4/12 E4 |
Date of sales availability | 2021-12-01 |
Dimension, weight | |
---|---|
Net weight, approx. m | 165 kg |
Installation and operating instructions
Certification booklet
Wilo-Flumen OPTI-TR 20-1 ... 40-1, Wilo-Flumen EXCEL-TRE 20 ... 40, Wilo-Flumen OPTI-TR 50-3 ... 120-1, Wilo-Flumen EXCEL-TRE 50-3 ... 90-2, Wilo-EMU TR 50-2 ... 120-1, Wilo-EMU TRE 50-2 ... 90-2, Wilo-EMU TR/TRE 212 ... 326-3
Article Number | 6074694 |
Edition | 2023-10 |
Number of pages | 68 |
Language | en |
PDF (37 MB)