Technical data
Hydraulic data
Maximum operating pressure PN 1 bar
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 50 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 50 °C
Max. fluid temperature, for short periods up to 30 min. T 75
Sound-pressure level 63.2 dB
Max. switching volume V 2 l
Macerator no
Motor data
Mains connection 1~230 V, 50 Hz
Rated current IN 3.4 A
Protection class IP68
Phase 1
Rated speed n 2800 1/min
Number of poles 2
Activation type Direct On Line (DOL)
Max. switching frequency t 20 1/h
Power consumption P1(Q=max.) of selected impeller * number of pumps P1 750 W
Operating mode (non-immersed) S3-15%
Insulation class F
Materials
Pump housing PP-GF20
Impeller PP-GF20
Shaft Stainless steel
Motor housing PPO/PA GF30
Installation dimensions
Pipe connection on the suction side DNs -
Pipe connection on the discharge side DNd DN 32

DrainLift MINI5-XS...

Product data
Brand Wilo
Product description DrainLift MINI5-XS/C-EF
Article number 6095129
EAN number 4062679278322
Colour White
Minimum order quantity 1
Date of sales availability 2024-10-01
Packaging
Packaging type Cardboard box
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 512 mm
Length L 455 mm
Height with packaging 410 mm
Height H 281 mm
Width with packaging 227 mm
Width W 167 mm
Gross weight, approx. m 10.4 kg
Net weight, approx. m 7.5 kg
Tender text

Compact lifting unit with alarm contact, ready for connection, for wash basin, shower, bathtub and condensing boiler drainage.

Fluid

For collection and pumping of the following in domestic areas:

  • Sewage not containing faeces
  • Condensate (as of pH value 2.5) – not in pure form, but rather mixed with sewage from another inlet.

Sewage pumping according to 12050

The sewage lifting unit meets the requirements of EN 12050-2.

Construction

Compact lifting unit with submersible pump, ready for connection. Level measurement performed by a level sensor. Venting is integrated in the inner cover and equipped with an active carbon filter. The lifting unit is also equipped with a buzzer and a potential-free alarm contact (max switching capacity: 42 V=, 500 mA, contact type: normally closed contact (NC)). If there is high water in the tank, an alarm sounds by means of the buzzer. An external alarm signal can also be connected via the potential-free contact. The tank lid seals the unit perfectly.

Up to four connections are available:

  • 1x 40 mm inlet (DN 40) without non-return valve, located on top, closed ex-works.
  • 2x 40/50 mm inlets (DN 40/50) with non-return valve, horizontal position on left and right side, open ex-works.
  • 1x 32/40 mm discharge port (DN 32/40) with non-return valve, located on top, open ex-works. If necessary, the discharge port can be positioned horizontally on the right side. The associated opening is closed ex-works.

Scope of delivery

  • 1x collar for HT pipe DN 32/40 (32/40 mm)
  • 2x 32–50 mm hose clips
  • 2x inlet connections DN 50 (50 mm)
  • 2x collars for HT pipe DN 40/50 (40/50 mm)
  • 2x non-return valve
  • 2x 50–70 mm pipe clamps
  • 2x 32–50 mm hose clips
  • 2x sealing plug
  • 6x O-rings
  • Install floor fixation (buoyancy safeguards): 2x mounting brackets with screws and wall plugs
  • Kit for emergency drainage (drainage hose, hose clip, sealing plug)
  • Kit for depth suction
  • Kit for horizontal discharge port
  • Installation and operating instructions
Operating Data
Approved field of application
Fluid temperature T 3 °C
Ambient temperature T 3 °C
Maximum operating pressure PN 1 bar
Max. switching volume V 2 l
Motor data
Mains connection 1~230 V, 50 Hz
Voltage tolerance ±10 %
Rated power P2 0.42 kW
Rated speed n 2800 1/min
Rated current IN 3.4 A
Insulation class F
Protection class motor IP68
Max. switching frequency t 20 1/h
Materials
Tank ABS
Pump housing PP-GF20
Impeller PP-GF20
Installation dimensions
Pipe connection on the suction side DN 40 (40 mm)
Pipe connection on the discharge side DN 32 (32 mm)
Ordering information
Brand Wilo
Product description DrainLift MINI5-XS/C-EF
Net weight, approx. m 7.5 kg
Article number 6095129
Documents

Operating instructions

Wilo-DrainLift MINI5-XS/C, Wilo-DrainLift MINI5-XS/WC

Article Number 6097575
Edition 2024-11
Number of pages 20
Language en
PDF (6 MB)

Installation instructions

Wilo-DrainLift MINI5-XS/C & MINI5-XS/WC

Article Number 6097578
Edition 2024-11
Number of pages 36
Language bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, ko, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk, zh
PDF (8 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

More suitable services

Supervision
Supervision Lifting stations (Single pump)
    
2219349

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation Lifting stations (Single pump)
    
2219384

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
Commissioning
Commissioning Lifting stations (Single pump)
    
2219412

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

Maintenance
Maintenance BASIC Lifting stations (Single pump)
    
2219541

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance COMFORT Lifting stations (Single pump)
    
2219515

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM Lifting stations (Single pump)
    
2219568

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

System Optimisation
System Optimisation Lifting stations (Single pump)
    
2219279

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions Lifting stations (Single pump)
    
2219314

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair Lifting stations (Single pump)
    
2219633

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report