Search
Contact
E-mail
Catalogue creation
My favorites
Wilo-SCP | Wilo
Your advantages
Wilo-SCP

Your advantages

  • Efficient hydraulics for high flow rates up to 17,000 m³/h
  • Low NPSH thanks to double suction impeller
  • High process reliability and easy maintenance without removing the pressure or suction lines
  • Decreased noise level and reduced vibrations
  • Options: energy efficient IE3-/IE4 motors, drinking water approval (KTW, ACS), innovative Ceram CT coating
Series description
SCP

Design

Axially spilt case pump mounted on a baseplate

Application

  • Pumping heating water in accordance with VDI  2035 water/glycol mixtures, cooling/cold water and domestic hot water
  • Applications in municipal water supply, irrigation, building services, general industry, power stations, etc.

Typekey

Example

SCP 200/250HA‐110/4

SCP

Axially split case pump

200

Nominal diameter of pressure port

250

Nominal diameter of impeller

HA

Hydraulics type A

HB

Hydraulics type B

Hs

Single suction impeller

DS

Two-stage pump

DV

Double volute

110

Rated motor power P2 [kW]

4

4-pole motor

Technical data

  • Fluid temperature (mechanical seal) [°C]:
    • -20 ~ 90 ° C Standard,
    • 90 ~ 120° C: High-temperature Type,
    • >120° C on request
  • Max.operating pressure [bar] :10/16/25
  • Mains connection:3~380V(±10%)-50Hz
  • Protection class:IP55
  • Insulation class: F
  • Energy efficiency class: CL 2
  • Number of motor poles/speed[rpm]:6 poles/980、4 poles/1480、2 poles/2900

Materials

  • Pump housing: EN-GJL-250
  • Impeller: G-CuSn10
  • Shaft: X12Cr13

Construction

  • Centrifugal axially split case pump, available in single-stage and two-stage design.
  • Delivered as complete unit (pump with coupling, coupling guard, motor and baseplate) or without motor or only pump hydraulics
  • Shaft sealing with mechanical seal or stuffing box packing
  • 2-, 4- and 6-pole motors; IE3-standard to 375 kW (IE4, IE2 on request)
  • Cast baseplate: SCP 200 and higher with welded steel frame (depending on the motor power and dimensions)

Scope of delivery

  • Pump
  • Installation and operating instructions
Documents

Installation and operating instructions

Wilo-SCP

Article Number 4144991
Edition 1910
Page format 209.9 x 297.0 mm
Number of pages 176
PDF (9 MB)

General overview

General Overview 2022 - International version

Edition 2022
Page format 209.9 x 297.0 mm
Number of pages 78
PDF (38 MB)

Certificate REACH

REACH Regulation

Edition 2021-05
Page format 209.9 x 297.0 mm
Number of pages 4
PDF (212 KB)

Reference sheet

Reference Sheet (English) - Power industry - Power Station Anpara, Anpara, India, 2014

Page format 203.9 x 290.0 mm
Number of pages 2
PDF (2 MB)
Product list
Number of results: 364
Product descriptionNumber of polesMotor efficiency classNominal flange diameterRated power P2Article number
SCP 50/180HA
4
IE3
DN 50
1.1 kW
SCP50_180HA-1,1_4_50Hz
SCP 50/180HA
4
IE3
DN 50
1.5 kW
SCP50_180HA-1,5_4_50Hz
SCP 50/220HA
4
IE3
DN 50
1.1 kW
SCP50_220HA-1,1_4_50Hz
SCP 50/220HA
4
IE3
DN 50
1.5 kW
SCP50_220HA-1,5_4_50Hz
SCP 50/220HA
4
IE3
DN 50
2.2 kW
SCP50_220HA-2,2_4_50Hz
SCP 50/340DS
4
IE3
DN 50
11 kW
SCP50_340DS-11_4_50Hz
SCP 50/340DS
4
IE3
DN 50
15 kW
SCP50_340DS-15_4_50Hz
SCP 50/340DS
4
IE3
DN 50
18.5 kW
SCP50_340DS-18,5_4_50Hz
SCP 50/340DS
4
IE3
DN 50
22 kW
SCP50_340DS-22_4_50Hz
SCP 50/340DS
4
IE3
DN 50
30 kW
SCP50_340DS-30_4_50Hz
SCP 50/340DS
4
IE3
DN 50
5.5 kW
SCP50_340DS-5,5_4_50Hz
SCP 50/340DS
4
IE3
DN 50
7.5 kW
SCP50_340DS-7,5_4_50Hz
SCP 50/340HA
4
IE3
DN 50
11 kW
SCP50_340HA-11_4_50Hz
SCP 50/340HA
4
IE3
DN 50
3 kW
SCP50_340HA-3_4_50Hz
SCP 50/340HA
4
IE3
DN 50
4 kW
SCP50_340HA-4_4_50Hz
SCP 50/340HA
4
IE3
DN 50
5.5 kW
SCP50_340HA-5,5_4_50Hz
SCP 50/340HA
4
IE3
DN 50
7.5 kW
SCP50_340HA-7,5_4_50Hz
SCP 65/390HS
4
IE3
DN 65
11 kW
SCP65_390HS-11_4_50Hz
SCP 65/390HS
4
IE3
DN 65
15 kW
SCP65_390HS-15_4_50Hz
SCP 65/390HS
4
IE3
DN 65
18.5 kW
SCP65_390HS-18,5_4_50Hz
SCP 65/390HS
4
IE3
DN 65
22 kW
SCP65_390HS-22_4_50Hz
SCP 65/390HS
4
IE3
DN 65
5.5 kW
SCP65_390HS-5,5_4_50Hz
SCP 65/390HS
4
IE3
DN 65
7.5 kW
SCP65_390HS-7,5_4_50Hz
SCP 80/200HA
2
IE3
DN 80
11 kW
SCP80_200HA-11_2_50Hz
SCP 80/200HA
2
IE3
DN 80
15 kW
SCP80_200HA-15_2_50Hz
SCP 80/200HA
2
IE3
DN 80
18.5 kW
SCP80_200HA-18,5_2_50Hz
SCP 80/200HA
2
IE3
DN 80
22 kW
SCP80_200HA-22_2_50Hz
SCP 80/230HA
4
IE3
DN 80
1.5 kW
SCP80_230HA-1,5_4_50Hz
SCP 80/230HA
4
IE3
DN 80
2.2 kW
SCP80_230HA-2,2_4_50Hz
SCP 80/230HA
4
IE3
DN 80
3 kW
SCP80_230HA-3_4_50Hz
SCP 80/230HA
4
IE3
DN 80
4 kW
SCP80_230HA-4_4_50Hz
SCP 80/230HA
4
IE3
DN 80
5.5 kW
SCP80_230HA-5,5_4_50Hz
SCP 80/340HA
4
IE3
DN 80
11 kW
SCP80_340HA-11_4_50Hz
SCP 80/340HA
4
IE3
DN 80
15 kW
SCP80_340HA-15_4_50Hz
SCP 80/340HA
4
IE3
DN 80
18.5 kW
SCP80_340HA-18,5_4_50Hz
SCP 80/340HA
4
IE3
DN 80
4 kW
SCP80_340HA-4_4_50Hz
SCP 80/340HA
4
IE3
DN 80
5.5 kW
SCP80_340HA-5,5_4_50Hz
SCP 80/340HA
4
IE3
DN 80
7.5 kW
SCP80_340HA-7,5_4_50Hz
SCP 80/360DS
4
IE3
DN 80
15 kW
SCP80_360DS-15_4_50Hz
SCP 80/360DS
4
IE3
DN 80
18.5 kW
SCP80_360DS-18,5_4_50Hz
SCP 80/360DS
4
IE3
DN 80
22 kW
SCP80_360DS-22_4_50Hz
SCP 80/360DS
4
IE3
DN 80
30 kW
SCP80_360DS-30_4_50Hz
SCP 80/360DS
4
IE3
DN 80
37 kW
SCP80_360DS-37_4_50Hz
SCP 80/360DS
4
IE3
DN 80
45 kW
SCP80_360DS-45_4_50Hz
SCP 80/380DS
4
IE3
DN 80
11 kW
SCP80_380DS-11_4_50Hz
SCP 80/380DS
4
IE3
DN 80
15 kW
SCP80_380DS-15_4_50Hz
SCP 80/380DS
4
IE3
DN 80
18.5 kW
SCP80_380DS-18,5_4_50Hz
SCP 80/380DS
4
IE3
DN 80
22 kW
SCP80_380DS-22_4_50Hz
SCP 80/380DS
4
IE3
DN 80
30 kW
SCP80_380DS-30_4_50Hz
SCP 80/380DS
4
IE3
DN 80
37 kW
SCP80_380DS-37_4_50Hz