Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison

More flexibility with integrated interfaces

Whether retrofitted or installed directly in the pump - Wilo products offer you various interfaces so that they can be optimally integrated into the building automation system.






Water Supply


High-pressure multistage centrifugal pumps

Integrated

Potential-free contracts

  • SSM
  • SBM

Digital interfaces

  • AUX

Analogue interfaces

  • 2 inputs
  • 0-10 V
  • 2-10 V
  • 0-20 mA
  • 4-20 mA

Twin-head function

  • available

Optional

Bus interfaces:

  • Modbus RTU/TCP
  • BACnet MS/TP
  • LON TP/FT-10
  • CANopen
  • PLR

Product example

  • Wilo-Helix EXCEL

Pressure-boosting systems

Integrated

Potential-free contracts:

  • SSM
  • SBM

Digital interfaces

  • extern AUX
  • AUX

Analogue interfaces

  • 0-20 mA
  • 4-20 mA

Twin-head function

  • available

Bus interfaces:

  • Modbus RTU

Optional

Bus interfaces:

  • Modbus RTU/TCP
  • BACnet MS/TP
  • LON TP/FT-10
  • Modbus TCP
  • BACnet/IP

Product example

  • Wilo-SiBoost Smart Helix EXCEL

Firefighting

Integrated

Potential-free contracts:

  • SSM

Twin-head function

  • available

Bus interfaces:

  • Modbus RTU

Optional

Bus interfaces:

  • SSM and ESM
  • SBM and EBM

Product example

  • Wilo-GEP Fire-H

Wastewater collection and transport


Solid seperation systems

Integrated

Potential-free contracts

  • SSM
  • SBM

Digital interfaces

  • high water alarm

Twin-head function

  • not available

Bus interfaces:

  • Modbus RTU

Optional

Bus interfaces:

  • BACnet MS/TP
  • LON TP/FT-10

Product example

  • Wilo-EMUport CORE

Drainage systems

Integrated

Potential-free contracts

  • SSM and ESM
  • SBM and EBM

Digital interfaces

  • high water alarm

Twin-head function

  • not available

Bus interfaces:

  • Modbus RTU

Optional

Bus interfaces:

  • BACnet MS/TP
  • LON TP/FT-10

Product example

  • Wilo-DrainLift SANI XL

Building Services


Smart pumps

Integrated

Potential-free contracts

  • SSM
  • SBM

Digital interfaces

  • Wilo-Stratos MAXO: 2 inputs, freely configurable
  • Wilo Stratos GIGA 2.0: 4 inputs, freely configurable

Analouge interfaces

  • 2 inputs
  • 0-10 V
  • 2-10 V
  • 0-20 mA
  • 4-20 mA
  • PT 1000

Twin-head function

  • available

Optional

Bus interfaces:

  • Modbus RTU/TCP
  • BACnet MS/TP
  • LON TP/FT-10
  • CANopen
  • PLR
  • Ethernet multiprotocol

Product example

  • Wilo-Stratos MAXO
  • Wilo-Stratos GIGA 2.0

Glanded pumps

Integrated

Potential-free contracts:

  • SSM
  • SBM

Digital interfaces

  • 2 inputs, freely configurable

Analouge interfaces

  • 2 inputs
  • 0-10 V
  • 2-10 V
  • 0-20 mA
  • 4-20 mA
  • DDG

Twin-head function

  • available

Optional

Bus interfaces:

  • Modbus RTU/TCP
  • BACnet MS/TP
  • LON TP/FT-10
  • CANopen
  • PLR
  • Ethernet multiprotocol

Product examples

Systems

Integrated

Potential-free contracts:

  • SSM
  • SBM

Digital interfaces

  • extern AUX
  • AUX

Analouge interfaces

  • 2 inputs
  • 0-10 V
  • 2-10 V
  • 0-20 mA
  • 4-20 mA

Twin-head function

  • available

Optional

Bus interfaces:

  • Modbus RTU
  • BACnet MS/TP
  • LON TP/FT-10
  • Modbus TCP
  • BACnet/IP
  • Modbus TCP
  • BACnet /IP

Product example

  • Wilo-SiFlux 3 IL-E





Example with the Wilo-Stratos MAXO:

Our Wilo-Stratos MAXO smart pump offers you analog and digital interface located directly in the terminal compartment of the pump. For connection to the building automation via a bus protocol, the retrofittable CIF module is used.

Building Automation Building Automation

Coloured terminals for safe and easy assignment as well as clear separation of electrical and communication connections (SELV)

ANALOGUE INTERFACES

  • 0 – 10 V, 2 – 10 V, 0 – 20 mA, 4 – 20 mA for the remote setpoint adjustment
  • PT1000 temperature sensor for the feed and/or return temperature


DIGITAL INTERFACES

Operational information and control commands can be transmitted to the building automation system via digital interfaces. Many Wilo products have digital inputs with which control modes can be triggered and duty points can be requested:

  • External OFF
  • External MAX
  • External MIN
  • External key lock
  • External MANUAL
  • Heating/cooling switchover


POTENTIAL-FREE CONTACT FOR SSM AND SBM

Fault or run signals are transmitted via potential-free contacts such as collective fault signal (SSM) or collective run signal (SBM):

  • SSM for fault feedback
  • SBM for pump operation feedback