| Technical data | |
|---|---|
| Min. ambient temperature | -20 °C |
| Max. ambient temperature | 40 °C |
| Electrical mains | 1~230 V ±10%, 50/60 Hz |
| Max. number of controllable pumps | 1 |
| Terminal cross-section | 1,5 mm² |
| Protection class | IPX4D |
| Interference emission | EN 61800-3;2004+A1;2012 /residential area (C1) |
| Interference resistance | EN 61800-3;2004+A1;2012 /industrial environment (C2) |
| Product data | |
|---|---|
| Brand | Wilo |
| Product description | Wilo-Connect module Yonos MAXO |
| Article number | 2210108 |
| EAN number | 4062679000732 |
| Colour | Black |
| Minimum order quantity | 1 |
| Date of sales availability | 2020-04-01 |
| Packaging | |
|---|---|
| Packaging type | Cardboard box |
| Packaging property | Sales packaging |
| Pieces per pallet | 256 |
| Number per layer | 32 |
| Dimension, weight | |
|---|---|
| Length with packaging | 200 mm |
| Length L | 120 mm |
| Height with packaging | 150 mm |
| Height H | 115 mm |
| Width with packaging | 131 mm |
| Width W | 105 mm |
| Gross weight, approx. m | 0,6 kg |
| Net weight, approx. m | 0,5 kg |
The Wilo-Connect module Yonos MAXO is a retrofittable plug-in module for Wilo-Yonos MAXO/Yonos MAXO-D/Yonos MAXO-Z pumps.
The Wilo-Connect module Yonos MAXO is installed on the electronic module of the pump at the position of the Wilo plug.
Utilisation of the Wilo-Connect moduleYonos MAXO dispenses with external contactors and other switchgears as well as the associated installation workload. The load of customer-side switchgears (relays) due to high starting currents is reduced to a minimum by the Connect module Yonos MAXO.
Equipment/function
- Run signal display
- SSM collective fault signal as potential-free NC contact
- SBM collective run signal as potential-free NO contact
- Overriding Off control input (External Off)
- Integrated dual pump management with the functions:
- Main/standby operation with runtime-dependent (24 h) switchover from main to standby pump
- Fault-sensitive switchover to operational standby pump
Mains terminals
Terminal cross-section: max. 2.5 mm2
Signal terminals
Max. switching capacity: 250 V/1 A
Terminal cross-section: max. 1.5 mm2
Control terminal Ext. Off
Contact rating: 24 V DC, 10 mA
Terminal cross-section: min. 0.75 mm2, max. 1.5 mm2
Scope of delivery
Wilo-Connect module Yonos MAXO
2 fastening screws for cover installation
4 threaded cable glands M16
Installation and operating instructions
| Ordering information | |
|---|---|
| Net weight, approx. | 0,5 kg |
| Make | Wilo |
| Item no. | 2210108 |