Yonos GIGA2.0-D 32/1-15/0,75-R1-S1
Article number : 2206037
| Hydraulic data | |
|---|---|
| Minimum efficiency index (MEI) | ≥0,4 |
| Maximum operating pressure PN | 16 bar |
| Min. fluid temperature Tmin | -20 °C |
| Max. fluid temperature Tmax | 120 °C |
| Min. ambient temperature Tmin | -30 °C |
| Max. ambient temperature Tmax | 50 °C |
| Drive | |
|---|---|
| Mains connection | 3~400 V, 50/60 Hz |
| Number of poles | 4 |
| Motor efficiency class | IE5 |
| Rated power P2 | 0,75 kW |
| Rated current IN | 1,4 A |
| Rated speed n | 2100 1/min |
| Max. speed nmax | 2360 1/min |
| Power consumption P1 max | 800 W |
| Emitted interference | EN 61800-3 |
| Interference resistance | EN 61800-3 |
| Insulation class | F |
| Protection class motor | IP55 |
| Threaded cable connection | 1 x M25x1.5 |
| Materials | |
|---|---|
| Pump housing | Grey cast iron |
| Impeller | PPE/PS-GF30 |
| Shaft | Stainless steel |
| Shaft seal | Q1Q1X4GG |
| Lantern | 5.1301/EN-GJL-250 KTL-coated |
| Approved liquids (other liquids upon request) | |
|---|---|
| Heating water (as per VDI 2035) | yes |
| Heat carrier oil | Special version at additional charge |
| Cooling and cold water circulation systems | yes |
| Water-glycol mixtures (at 20 – 40 vol. % glycol and fluid temperature ≤ 40 °C) | yes |
| Installation dimensions | |
|---|---|
| Port-to-port length L0 | 260 mm |
| Pipe connection on the suction side DNs | DN 32 |
| Pipe connection on the discharge side DNd | DN 32 |
Yonos GIGA2.0-D 32/1-15/0,75-R1-S1
3~ 380 V...440 V, 50/60 Hz
Airborne sound data sheet
| Airborne sound power LW,A | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 20µPa |
| L63 | 31,5 |
| L125 | 35,6 |
| L250 | 55,2 |
| L500 | 58,9 |
| L1000 | 62,9 |
| L2000 | 60,6 |
| L4000 | 52,4 |
| L8000 | 46,1 |
| Airborne sound-power level (total) Lw | 70,7 db(A) |
| Airborne sound pressure Lp,A,1m | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 1pW |
| L63 | 17,5 |
| L125 | 21,6 |
| L250 | 41,2 |
| L500 | 44,9 |
| L1000 | 48,9 |
| L2000 | 46,6 |
| L4000 | 38,4 |
| L8000 | 32,1 |
| Airborne sound-pressure level (total) Lp | 56,7 db(A) |
The acoustic values given are based on measurements and in some cases on calculations and may deviate by up to 3 dB.
| Product data | |
|---|---|
| Brand | Wilo |
| Product description | Yonos GIGA2.0-D 32/1-15/0,75-R1-S1 |
| Article number | 2206037 |
| EAN number | 4062679112404 |
| Colour | Green/black/grey |
| Minimum order quantity | 1 |
| Date of sales availability | 2022-05-01 |
| Packaging | |
|---|---|
| Packaging type | Euro pallet |
| Packaging property | Transport packaging |
| Pieces per pallet | 1 |
| Number per layer | 1 |
| Dimension, weight | |
|---|---|
| Length with packaging | 1200 mm |
| Length L | 516 mm |
| Height with packaging | 800 mm |
| Height H | 376 mm |
| Width with packaging | 800 mm |
| Width W | 692 mm |
| Gross weight, approx. m | 96 kg |
| Net weight, approx. m | 49 kg |