Data sheet
| Hydraulic data | |
|---|---|
| Maximum operating pressure PN | 10 bar |
| Min. fluid temperature Tmin | -20 °C |
| Max. fluid temperature Tmax | 120 °C |
| Min. ambient temperature Tmin | -15 °C |
| Max. ambient temperature Tmax | 40 °C |
| Motor data | |
|---|---|
| Mains connection | 3~400 V, 50 Hz |
| Number of poles | 2 |
| Voltage tolerance | ±10 % |
| Motor efficiency class | IE2 |
| Rated power P2 | 0.12 kW |
| Rated current IN | 0.38 A |
| Rated speed n | 2875 1/min |
| Power factor cos φ100 | 0.75 |
| Motor efficiency 50% ηM 50% | 50.1 % |
| Motor efficiency 75% ηM 75% | 57.4 % |
| Motor efficiency 100% ηM 100% | 60.8 % |
| Insulation class | F |
| Protection class motor | IP55 |
| Materials | |
|---|---|
| Pump housing | Grey cast iron |
| Impeller | PP-LGF50 |
| Shaft | Stainless steel |
| Mechanical seal | Q1Q1X4GG |
| Installation dimensions | |
|---|---|
| Pipe connection, suction side DNs | G 2 |
| Pipe connection, discharge side DNd | G 2 |
| Port-to-port length L0 | 180 mm |
Pump curves
Dimensions and dimensions drawings
VeroLine-IPL 30/70-0,12/2

Wiring diagram

∆: Connection diagram delta connection
Y: Connection diagram star connection
Motor protection switch required on-site. Check the direction of rotation! To change the direction of rotation, exchange any two phases.
| P2≤ 3 kW | 3~400 V Y |
| 3~230 V ∆ | |
| P2≥ 4 kW | 3~690 V Y |
| 3~400 V ∆ |
After removing the bridges, Y-∆ start is possible.
Acoustics
Airborne sound data sheet
| Airborne sound power LW,A | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 20µPa |
| L63 | 31.1 |
| L125 | 22.3 |
| L250 | 36.5 |
| L500 | 41.2 |
| L1000 | 50.3 |
| L2000 | 52.7 |
| L4000 | 48.7 |
| L8000 | 37.5 |
| Airborne sound-power level (total) Lw | 56 |
| Airborne sound pressure Lp,A,1m | |
|---|---|
| Octave band centre frequency in Hz | Level in dB(A), ref. 1pW |
| L63 | 16.6 |
| L125 | 7.8 |
| L250 | 22 |
| L500 | 26.7 |
| L1000 | 35.8 |
| L2000 | 38.2 |
| L4000 | 34.2 |
| L8000 | 23 |
| Airborne sound-pressure level (total) Lp | 41 |
Ordering information
| Product data | |
|---|---|
| Brand | Wilo |
| Product description | VeroLine-IPL 30/70-0,12/2-S1 |
| Article number | 2163041 |
| EAN number | 4048482605975 |
| Colour | Green |
| Minimum order quantity | 1 |
| Date of sales availability | 2010-09-01 |
| Packaging | |
|---|---|
| Packaging type | Cardboard box |
| Packaging property | Transport packaging |
| Pieces per pallet | 1 |
| Number per layer | 8 |
| Dimension, weight | |
|---|---|
| Length with packaging | 400 mm |
| Length L | 318 mm |
| Height with packaging | 263 mm |
| Height H | 180 mm |
| Width with packaging | 300 mm |
| Width W | 123 mm |
| Gross weight, approx. m | 10 kg |
| Net weight, approx. m | 8 kg |
Single-stage glanded centrifugal pump with compact in-line design with directly flanged three-phase current motor and one-piece shaft or with lantern and standard motor rigidly connected by coupling (N version). The IPL series is suitable for pipe installation or installation on a base. Mounting brackets are available as accessories. With force-flushed circulation, bidirectional bellows mechanical seal and cavitation-reducing plastic impeller.
Flanges with pressure measuring connections R 1/8. The pump housing and lantern are cataphoretic-coated.
The motor terminal box can be made of metal or plastic. If a metal terminal box is absolutely necessary, please order the appropriate special variant.
| Operating data | |
|---|---|
| Min. fluid temperature Tmin | -20 °C |
| Max. fluid temperature Tmax | 120 °C |
| Min. ambient temperature Tmin | -15 °C |
| Max. ambient temperature Tmax | 40 °C |
| Maximum operating pressure PN | 10 bar |
| Motor data | |
|---|---|
| Motor efficiency class | IE2 |
| Mains connection | 3~400 V, 50 Hz |
| Voltage tolerance | ±10 % |
| Rated power P2 | 120 W |
| Rated speed n | 2875 1/min |
| Rated current IN | 0.38 A |
| Power factor cos φ100 | 0.75 |
| Motor efficiency 50% ηM 50% | 50.1 % |
| Motor efficiency 75% ηM 75% | 57.4 % |
| Motor efficiency 100% ηM 100% | 60.8 % |
| Insulation class | F |
| Protection class | IP55 |
| Materials | |
|---|---|
| Pump housing | Grey cast iron |
| Impeller | PP-LGF50 |
| Shaft | Stainless steel |
| Shaft seal | Q1Q1X4GG |
| Lantern | Grey cast iron |
| Installation dimensions | |
|---|---|
| Pipe connection, suction side DNs | G 2 |
| Pipe connection, discharge side DNd | G 2 |
| Port-to-port length L0 | 180 mm |
| Ordering information | |
|---|---|
| Brand | Wilo |
| Product description | VeroLine-IPL 30/70-0,12/2-S1 |
| Net weight, approx. m | 8 kg |
| Article number | 2163041 |