EMUport CORE 20.2-21/540

Article number : 2554529
EUR 29,143.-
Price (excl. VAT)
Price group : PG8
Technical data
Hydraulic data
Maximum operating pressure PN 2 bar
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 40 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 40 °C
Switching volume V 295 l
Macerator no
Motor data
Mains connection 3~400 V, 50 Hz
Rated current IN 5,7 A
Phase 3
Rated speed n 2908 1/min
Number of poles 2
Activation type Direct On Line (DOL)
Max. switching frequency t 60 1/h
Power consumption P1(Q=max.) of selected impeller * number of pumps P1 3100 W
Motor efficiency class IE3
For Wilo pumps Rexa PRO C08DA-434 + P13.2-16/EAD3-2-T
Insulation class F
Protection class IP68
Materials
Pump housing Grey cast iron
Impeller Grey cast iron
Shaft Stainless steel
Motor housing Grey cast iron
Installation dimensions
Operating mode (non-immersed) S1
Pipe connection on the discharge side DN 80
Pipe connection on the suction side DN 200

Wilo-EMUport CORE 20.2

Prices
Price (excl. VAT) EUR 29,143.-
Price group PG8
Product data
Brand Wilo
Product description EMUport CORE 20.2-21/540
Article number 2554529
EAN number 4062679160740
Colour black/silver
Minimum order quantity 1
Date of sales availability 2021-11-01
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1500 mm
Length L 1390 mm
Height with packaging 1580 mm
Height H 1430 mm
Width with packaging 1500 mm
Width W 1410 mm
Gross weight, approx. m 436 kg
Net weight, approx. m 386 kg
Tender text

Fully submersible sewage lifting unit, ready for connection, with solids separation according to DIN EN 12050-1. Due to the version as a solids separation system, the coarse solids are separated before the pumps and do not come into contact with the pumps. This ensures maximum operational reliability. All-in-one gas-tight and watertight collection reservoir without constructive welded joints, as well as two separately-lockable and externally maintainable solids separation reservoirs. Individual shut-off makes it possible to carry out maintenance work during operation. Pumping is performed by two high-performance submersible sewage pumps in dry well installation that run in alternating operation. The dry well installation of the pumps and their configuration as a redundant double-pump system ensures maximum hygiene, ease of maintenance, and operational reliability. The collection reservoir has rounded edges, the tank bottom is bevelled, the deepest point is located directly below the pump. This prevents deposits and the drying of solids at critical points. Quick connector to the pumps and the inspection opening facilitate maintenance work. Separate blocking of the solids separation reservoir facilitate maintenance while the unit is in operation. Manual backwashing in the collection reservoir reinforces the cleaning effect through additional turbulences and the transparent cover on the distributor box allows easy visual inspection of the unit. Level control is carried out using a level probe.

Scope of delivery

  • Submersible pump solids separation system with two dry well installation submersible pumps
  • 2x gate valve for solids separation reservoir
  • 2x non-return valve on the discharge side in rectangular design
  • 2x gate valve on the discharge side
  • Consolidation of the pressure outlet line
  • 1x level probe
  • 1x floor fixation as cross beam
  • 2.5 m ventilation and venting hose
  • 1x maintenance kit with blind flange

Recommended accessories

  • Wilo-Control SC-L-…-FTS switchgear
  • Inlet slide valve
  • Rinsing kit for supply box
Operating Data
For Wilo pumps Rexa PRO C08DA-434 + P13.2-16/EAD3-2-T
Approved field of application
Fluid temperature T 3 °C
Max. fluid temperature, for short periods up to 3 min. T 40 °C
Ambient temperature T 3 °C
Maximum operating pressure PN 2 bar
Max. permissible pressure in the pressure pipe P 6 bar
Product data
Gross volume of the tank V 440 l
Switching volume V 295 l
Operating mode (non-immersed) S1
Height H 1430 mm
Length L 1390 mm
Width W 1410 mm
Diagonal dimension Diagonal axis 1500 mm
Motor data
Mains connection 3~400 V, 50 Hz
Voltage tolerance ±10 %
Rated power P2 2,65 kW
Rated speed n 2908 1/min
Rated current IN 5,7 A
Insulation class F
Protection class motor IP68
Activation type Direct On Line (DOL)
Max. switching frequency t 60 1/h
Motor protection Bimetall
Cable
Connection cable length L 20 m
Cable type TGSH-J
Cable cross-section 7G1,5 mm²
Mains plug no
Type of connection cable Detachable
Materials
Tank PE
Pump housing Grey cast iron
Impeller Grey cast iron
Shaft Stainless steel
Gasket material NBR
Motor housing Grey cast iron
Installation dimensions
Pipe connection on the suction side DN 200
Pipe connection on the discharge side DN 80
Connection venting Ø 75
Ordering information
Brand Wilo
Product description EMUport CORE 20.2-21/540
Net weight, approx. m 386 kg
Article number 2554529
Documents

Installation and operating instructions

Wilo-EMUport CORE

Article Number 6092612
Edition 2022-01
Number of pages 32
Language en
PDF (6 MB)

Wilo-Control SC-L...-FTS

Article Number 2545546
Edition 08-2016
Number of pages 112
Language de, en, es, fr, hu
PDF (13 MB)

Certification booklet

Wilo-EMUport Core 20.2 / 45.2 / 50.2 / 60.2

Article Number 2546469
Edition 2021-07
Number of pages 40
Language ar, az, ba, bg, cs, da, de, el, en, es, et, fi, fr, ga, hr, hu, it, ko, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sq, sr, sv, tr, uk, zh
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (271 KB)
BIM/CAD
Accessory

Level control with level sensor (4)

Stationary dry well installation (21)

Adapter (6)

Fittings (2)

Installation/setup (7)

Pipes/pipe joints (7)

Pump control (3)

Pump control/accessories (1)

Alarm signal (5)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance COMFORT EMUport Core
    

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

WiloCare
WiloCare Comfort
    

WiloCare ist eine digitale Lösung zur Fernüberwachung von Wilo-Pumpen und Pumpensystemen.

Das WiloCare-Konzept steht auf zwei Säulen: der fachgerechten Instandhaltung sowie der digitalen Anlagenüberwachung inkl. sofortiger Information bei Störungen oder Warnmeldungen.

Dafür wird die Anlage mit zusätzlicher Hardware ausgestattet, welche die gewünschten Anlagenparameter direkt in einem individuellen Dashboard, dem Wilo-Monitor, visualisiert. Der Zugriff auf den Wilo-Monitor ist jederzeit mittels PC, Tablet oder Smartphone möglich.

Die benötigte Hardware wird dem Auftraggeber während der Dauer des WiloCare-Vertrags von WILO zur Verfügung gestellt. Es können bis zu 20 Anlagen an die gleiche Hardware angeschlossen werden.

Die Datenübertragen erfolgt via Modbus oder bestehenden Meldekontakten.

Dank der Datenübertragung, werden Störungen und Warnmeldungen sofort via E-Mail oder SMS an den Kunden übermittelt.

Fehler können dadurch schnell und präventiv erkannt und verhindert werden, sodass die Betriebssicherheit der angebundenen Anlagen langfristig abgesichert ist.

Das WiloCare Comfort-Paket umfasst:

  • Wilo-Smart Gateway und zusätzlich benötigte Hardware (Router, SIM-Karte, Antenne, separates Gehäuse)
  • Installation und Inbetriebnahme von WiloCare durch den Wilo-Werkskundendienst
  • Einrichtung des Wilo-Monitors mit definierten Anlagen-Parametern (z.B. Betriebsstunden, Füllstände, Druck oder Betriebszustand)
  • 24 Stunden erreichbare und kostenfreie Notfallrufnummer
  • Überwachung der Anlage durch den Kunden
  • Datenhistorie der letzten Monate
WiloCare Comfort Plus
    

WiloCare ist eine digitale Lösung zur Fernüberwachung von Wilo-Pumpen und Pumpensystemen.

Das WiloCare-Konzept steht auf zwei Säulen: der fachgerechten Instandhaltung sowie der digitalen Anlagenüberwachung inkl. sofortiger Information bei Störungen oder Warnmeldungen.

Dafür wird die Anlage mit zusätzlicher Hardware ausgestattet, welche die gewünschten Anlagenparameter direkt in einem individuellen Dashboard, dem Wilo-Monitor, visualisiert. Der Zugriff auf den Wilo-Monitor ist jederzeit mittels PC, Tablet oder Smartphone möglich.

Die benötigte Hardware wird dem Auftraggeber während der Dauer des WiloCare-Vertrags von WILO zur Verfügung gestellt. Es können bis zu 20 Anlagen an die gleiche Hardware angeschlossen werden.

Die Datenübertragen erfolgt via Modbus oder bestehenden Meldekontakten.

Dank der Datenübertragung, werden Störungen und Warnmeldungen sofort via E-Mail oder SMS an den Kunden übermittelt.

Fehler können dadurch schnell und präventiv erkannt und verhindert werden, sodass die Betriebssicherheit der angebundenen Anlagen langfristig abgesichert ist.

In der WiloCare Comfort PLUS-Ausführung, übernimmt Wilo die Überwachung der Anlagen innerhalb der regulären Öffnungszeiten. Auftretende Störungen und Fehlermeldungen werden schnell und proaktiv von Wilo nachverfolgt und behoben.

Das Comfort WiloCare PLUS-Paket umfasst:

  • Wilo-Smart Gateway und zusätzlich benötigte Hardware (Router, SIM-Karte, Antenne, separates Gehäuse)
  • Installation und Inbetriebnahme von WiloCare durch den Wilo-Werkskundendienst
  • Einrichtung des Wilo-Monitors mit definierten Anlagen-Parametern (z.B. Betriebsstunden, Füllstände, Druck oder Betriebszustand)
  • 24 Stunden erreichbare und kostenfreie Notfallrufnummer
  • Überwachung der Anlage durch den Kunden
  • Überwachung der Anlage durch Wilo (innerhalb der regulären Öffnungszeiten)
  • Datenhistorie der letzten Monate
Commissioning
Commissioning EMUport Core
    

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

More suitable services

Extended Warranty
Extended Warranty EMUport Core
    

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service