Product design type | Glanded energy-saving twin-head pump | Glandless premium smart twin-head pump | Glanded standard twin-head pump | Existing pump |
| | | | |
| | | | |
| | | | |
Description | |
Product description | Yonos GIGA2.0-D 65/1-14/2,2 | Stratos MAXO-D 65/0,5-16 PN 6/10 | VeroTwin-DPL 65/115-1,5/2 | 63/4175/4185/4188 PN10 |
Article number | 2205887 | 2164659 | 2121261 | - |
Series | Wilo-Yonos GIGA2.0-D | Wilo-Stratos MAXO-D | Wilo-VeroTwin-DPL | - |
Mains connection | 3~380 V ±10%, 50/60 Hz | - | - | - |
| 3~400 V ±10%, 50/60 Hz | - | - | - |
| 3~440 V ±10%, 50/60 Hz | - | - | - |
| - | 1~230 V ±10%, 50/60 Hz | - | - |
| - | - | 3~400 V ±10%, 50 Hz | - |
Port-to-port length | 340 mm | 340 mm | 340 mm | 400 mm |
Pump connection | DN 65 | DN 65 | DN 65 | - |
Display | Graphic colour display (2 inches) | Graphic colour display (4.3 inches) | - | - |
Comment | Works with other accessories without the need to change any piping | Works with other accessories without the need to change any piping
Check electrical connection | Works with other accessories without the need to change any piping | - |
Fitting piece (PN10/16) | 2 x 110624390 Intermediate flange pieces F 11, DN 65x30mm, PN 10/16 | 2 x 110624390 Intermediate flange pieces F 11, DN 65x30mm, PN 10/16 | 2 x 110624390 Intermediate flange pieces F 11, DN 65x30mm, PN 10/16 | - |
Function | |
Control mode | Δp-v for variable differential pressure | Δp-v for variable differential pressure | - | - |
| Δp-c for constant differential pressure | Δp-c for constant differential pressure | - | - |
| User-defined PID control | User-defined PID control | - | - |
| Constant speed (n-const.) | Constant speed (n-const.) | - | - |
| - | Q limit for limiting the maximum volume flow | - | - |
| - | Dynamic Adapt plus | - | - |
| - | ΔT-const. for constant differential temperature control | - | - |
| - | T-const. for constant temperature control | - | - |
| - | Constant Q for constant volume flow control | - | - |
| - | Multi Flow Adaptation | - | - |
| - | Δ T-const. for constant differential temperature control | - | - |
Special features of the series | - | Heating/Cooling switching | - | - |
| - | Night set back | - | - |
| - | Heat quantity measurement | - | - |
| - | Cooling quantity measurement | - | - |
| - | Key locking function | - | - |
| - | No-Flow Stop | - | - |
| - | Reset function to factory setting | - | - |
| - | Adjustable volume flow limiter | - | - |
| - | Ability to save and restore configured pump settings (3 restoration points) | - | - |
| - | Fault message and warning message in plain text including suggested remedy | - | - |
Multi pump operation | Main/Standby | Main/Standby | - | - |
| Parallel operation | Parallel operation | - | - |
Measurement value logging | - | Heat and cooling capacity measurement | - | - |
Display | Actual delivery head | Actual delivery head | - | - |
| Actual volume flow | Actual volume flow | - | - |
| Actual power consumption | Actual power consumption | - | - |
| Energy consumption | Energy consumption | - | - |
| Current operating status and data, as well as faults | - | - | - |
| Warning messages in plain text (display status: yellow) | Warning messages in plain text (display status: yellow) | - | - |
| Error messages in plain text (display: red) | Error messages in plain text (display: red) | - | - |
| - | Setpoint | - | - |
| - | Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - | - |
| - | Pump venting (display status: blue) | - | - |
| - | Control mode | - | - |
| - | Active influences (e.g. STOP) | - | - |
Display (can also be selected) | - | Speed | - | - |
| - | Heating quantity | - | - |
| - | Cooling quantity | - | - |
| - | Operating hours | - | - |
| - | Mains voltage | - | - |
| - | Warning message | - | - |
| - | Error message | - | - |
Pump venting function | - | Yes | - | - |
Dry-running detection | - | yes | - | - |
Equipment | |
Cable glands for sensors and communication | Mains connection | - | - | - |
| Communication | - | - | - |
Thermal insulation shell | - | No | - | - |
Cold water insulation shell | - | No | - | - |
Quick electrical connection | - | Wilo Connector | - | - |
Blocking-current proof motor | - | yes | - | - |
Particle filter | - | yes | - | - |
Key lock | - | yes | - | - |
Fluid temperature sensor | - | Integrated | - | - |
Connectivity | |
Analogue signal as standard | 0-10 V | 0-10 V | - | - |
| 2-10 V | 2-10 V | - | - |
| 4-20 mA | 4-20 mA | - | - |
| 0-20 mA | 0-20 mA | - | - |
| - | PT1000 | - | - |
Digital output | SSM or SBM | - | - | - |
| - | SSM | - | - |
| - | SBM | - | - |
Digital input | Ext. OFF | Ext. OFF | - | - |
| - | Ext. MIN | - | - |
| - | Ext. MAX | - | - |
| - | MANUAL (BMS-OFF) | - | - |
| - | Key lock | - | - |
| - | Switchover between heating/cooling mode | - | - |
Bus communication via additional accessories | BACnet MS/TP | BACnet MS/TP | - | - |
| LON | LON | - | - |
| Modbus RTU | Modbus RTU | - | - |
| CANopen | CANopen | - | - |
| PLR | PLR | - | - |
| Ethernet | - | - | - |
| - | BACnet IP | - | - |
| - | Modbus TCP | - | - |
Access via the Wilo-Assistant app | - | Yes | - | - |
Connection for Wilo-Smart Cloud | - | Via Wilo-Smart Gateway | - | - |
wire data exchange and remote operation | - | Bluetooth | - | - |
Motor data | |
Phases | 3 | 1 | 3 | 3 |
Mains connection | 3~400 V, 50/60 Hz | 1~230 V, 50/60 Hz | 3~400 V, 50 Hz | 3~400 V, 50 Hz |
Energy efficiency index (EEI) %%fn=footnote%% | - | ≤0,17 | - | - |
Min current | - | 0,3 A | - | - |
Max current | - | 6,23 A | - | - |
Rated power | 2200 W | 1238 W | 1500 W | - |
Min. speed | 500 1/min | 500 1/min | - | - |
Max. speed | 2890 1/min | 3200 1/min | - | - |
Power consumption | - | 20 W | - | - |
Power consumption | 2400 W | 1440 W | - | - |
Emitted interference | EN 61800-3 | EN 61800-3;2004+A1;2012 /residential area (C1) | - | - |
Interference resistance | EN 61800-3 | EN 61800-3;2004+A1;2012 /industrial environment (C2) | - | - |
Insulation class | F | F | F | - |
Protection class | IP55 | IPX4D | IP55 | - |
Materials | |
Material | Grey cast iron | Grey cast iron | Grey cast iron | - |
Impeller | PPE/PS-GF30 | PPS-GF40 | PPE/PS-GF30 | - |
Shaft | Stainless steel | 1.4028, DLC-coated | Stainless steel | - |
Bearing | - | Carbon, antimony-impregnated | - | - |
Pipe connection | |
Inlet connection | DN 65 | DN 65 | DN 65 | - |
PN connection on suction side | PN 16 | PN 6/10 | PN 10 | - |
Outlet connection | DN 65 | DN 65 | DN 65 | DN 65 |
PN connection on discharge side | PN 16 | PN 6/10 | PN 10 | PN 10 |
Dimension, weight | |
Length with packaging | 1200 mm | 800 mm | 800 mm | - |
Length | 517 mm | 340 mm | 483 mm | - |
Height with packaging | 800 mm | 525 mm | 525 mm | - |
Height | 408 mm | 464 mm | 340 mm | - |
Width with packaging | 800 mm | 600 mm | 600 mm | - |
Width | 794 mm | 570 mm | 432 mm | - |
Gross weight, approx. | 116 kg | 66,8 kg | 78 kg | - |
Net weight, approx. | 67 kg | 63,5 kg | 72 kg | - |
Ordering information | |
Product description | Yonos GIGA2.0-D 65/1-14/2,2 | Stratos MAXO-D 65/0,5-16 PN 6/10 | VeroTwin-DPL 65/115-1,5/2 | 63/4175/4185/4188 PN10 |
Brand | Wilo | Wilo | Wilo | Vadstena |
EAN number | 4062679110141 | 4048482700014 | 4048482215440 | - |
Article number | 2205887 | 2164659 | 2121261 | - |