Article number: 4254793
Technical data
Hydraulic data
Maximum operating pressure PN 8 bar
Discharge port G 1¼
Max. volume flow Qmax 4.1 m³/h
Optimal volume flow Qopt 3.0 m³/h
Max. delivery head Hmax 48.7 m
Optimal delivery head Hopt 29.39 m
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 1~230 V, 50 Hz
Shaft power P2(Q=max.) of selected impeller * number of pumps NO VALUE 550 W
Rated speed n 2900 1/min
Rated current IN 3.6 A
Power factor cos φ100 0.98
Protection class motor IP55
Insulation class F
Materials
Pump housing Stainless steel
Impeller PPE/PS-GF30
Shaft Stainless steel
Shaft seal BQ1EGG
Installation dimensions
Gross volume of the tank V 150 l
Gross volume of the diaphragm expansion tank V 8 l
Pipe connection on the suction side DNs G 1¼
Pipe connection on the discharge side DNd G 1¼

Wilo-Medana AF150

Product data
Brand Wilo
Product description RainSystem AF 150-2 Medana LSP205/EC
Article number 4254793
EAN number 4062679354736
Colour Green/black/silver
Minimum order quantity 1
Date of sales availability 2024-07-01
Packaging
Packaging type One-way pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1200 mm
Length L 870 mm
Height with packaging 1690 mm
Height H 1470 mm
Width with packaging 800 mm
Width W 745 mm
Gross weight, approx. m 129 kg
Net weight, approx. m 105 kg
Tender text

Compact rainwater utilisation system compliant with DIN 1989-100 and DIN EN 16941-1 with flexible manifold on the discharge side and two separate suction line connections to save drinking water. Made up of two low-noise, self-priming, horizontal high-pressure multistage centrifugal pumps from the Wilo-Medana CH1-LSP series. Mounted on a tubular steel frame with height-adjustable pedestal, ready for connection, including switchgear for comfortable system control.

Fully automated rainwater utilisation or fresh water replenishment in case of drought in multi-residential buildings and small commercial businesses.

Special features/Product advantages

  • Compact, factory pre-assembled design enables easy installation
  • Simple and intuitive operation via EC switchgear combined with Green Button Technology
  • Automatic replenishment with drinking water permits reliable, continuous operation even in drought conditions
  • Flow-optimised design and use of IE2 motors enable energy-saving operation
  • Self-protection routines, control in the low voltage range, the use of corrosion-resistant components and the optional integration into a building management system facilitate high operational reliability
  • Maintenance notifications in the fault display via error codes
  • The integration into building automation via standard Modbus and optional extended communication via Wilo-Gateway enables remote monitoring
  • Quiet operation for high level of user comfort

Equipment/function

  • Two high-pressure multistage centrifugal pump from the Wilo-Medana CH1-LSP series with IE2 motor technology
  • Tubular steel frame in a vibration-insulated design with height-adjustable pedestal and baseplate for attaching pumps
  • Two three-way valves allow automatic switchover to drinking water replenishment in case of a lack of rainwater in the storage tank
  • Replenishment reservoir (volume: 150 litres) with overflow conforming to EN 1717 (free drain type AB) and demand-oriented replenishment of fresh water when rainwater storage tank is empty
  • Throughflow diaphragm expansion tank (volume: 8 litres) conforming to DIN 4807 for energy savings if there are very small leaks in the building
  • Filling level sensor with 20 m cable (measurement range 0 to 5 m) allows the amount of water in the rainwater storage tank to be detected
  • All parts that come into contact with the fluid are corrosion-proof

on the discharge side:

  • Ball valve at each pump
  • Discharge manifold that can be connected on both sides
  • Throughflow diaphragm expansion tank (8 litres)
  • Pressure sensor 4 – 20 mA
  • Pressure gauge
  • Threaded cap or blind flange depending on the nominal diameter of the manifold (must be ordered separately)

on the suction side:

  • Two separate suction line connections (for separate installation of the floating extractor in the rainwater storage tank)
  • Ball valve at each pump
  • Pressure sensor 4 – 20 mA
  • Pressure gauge
  • Threaded cap or blind flange depending on the nominal diameter of the manifold (must be ordered separately)

Automatic pump control via fully electronic EC-Rain switchgear (Easy Control) in a metallic housing, protection class IP54. Ready for connection as electronics and hydraulics are already hooked up. Mounted on an anti-corrosive, painted tubular steel frame.

A working area of 60 cm around the system is recommended in order to facilitate the maintenance process.

Operation/display

  • LED display to output operating data, controller parameters, operating statuses of the pumps, error messages and history memory
  • Menu navigation with seven-segment display and visualisation
  • Factory-preset parameters for easy commissioning/start
  • Setting of operating parameters and acknowledgement of fault messages using rotary knob
  • Lockable main switch
  • Elapsed time indicator for each pump and for the entire system
  • Dry-running and overflow meter
  • Fault memory for the last 10 faults

Control

  • Two self-priming centrifugal pumps from the Wilo-Medana CH1-LSP series (p-c control mode)
  • Adjustable switch-on and -off pressure for base- and peak-load pump in relation to the defined duty point
  • Automatic, load-sensitive cut-in of the peak-load pump depending on the start-up pressure of the base-load pump
  • Easy Actions menu for quick configuration of basic parameters
  • Freely selectable operating mode of pump (manual, off, automatic) and three-way valves (opened, closed)
  • Steady system control by means of pump cycling and integrated test run on idle pumps
  • Operating modes of the systems (manual or automatic)
  • Automatic, configurable pump cycling
    • Standard setting: Impulse - The base-load pump is cycled at each new demand, regardless of operating hours
    • Additional: pump cycling of base-load pump after set number of operating hours (interval: 1 to 6 hours)
  • Automatic, configurable pump test run (pump kick)
    • Can be activated/deactivated
    • Time between two pump test runs is freely programmable
    • Disabling times can be programmed as desired

Monitoring

  • System/level control in low-voltage range (24VDC)
  • Level monitoring of the rainwater storage tank with overflow detection and metering
  • Optional overflow detection for replenishment reservoir
  • Over/underpressure detection
  • Dry-running protection of pump
  • Self-priming support
  • Calcination protection of the three-way valve
  • Automatic periodic water exchange in the replenishment reservoir (intervals selectable)
  • Collective run and fault signals via potential-free contacts
  • Optional inputs/outputs (see interfaces)

Interfaces

  • Potential-free contacts for SBM/SSM collective run and collective fault signals
  • Logic reversal can be applied to SBM and SSM
  • Optional inputs: Contacts for dry run (delay of 1 to 180 seconds), external off, overflow (replenishment reservoir/rainwater storage tank), return (rainwater storage tank), dry run (rainwater storage tank)
  • Optional outputs: two outputs with -60 to 60 second offset in relation to pump outputs 1 & 2 (if three-way valve is in the rainwater mode)

Recommended accessories (to be ordered separately)

  • Two separate suction hoses and suction filters (floating extractor)
  • Diaphragm expansion tank on the discharge side pursuant to conditions and requirements

Optional accessories

  • Threaded cap or blind flange depending on the nominal diameter of the manifold
  • Filter (on the discharge side)

Bus systems

  • Modbus RTU
Materials
Pump housing Stainless steel
Shaft Stainless steel
Impeller PPE/PS-GF30
Operating Data
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Maximum operating pressure p 10.0 bar
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 1~230 V, 50 Hz
Rated speed n 2900 1/min
Rated current IN 3.6 A
Power factor cos φ100 0.98
Protection class motor IP55
Insulation class F
Installation dimensions
Overflow connection Ø110-PN0
Pipe connection on the suction side DNs G 1¼
Pipe connection on the discharge side DNd G 1¼
Ordering information
Net weight, approx. m 105 kg
Brand Wilo
Product description RainSystem AF 150-2 Medana LSP205/EC
Article number 4254793
Documents

Installation and operating instructions

Wilo-Medana CH1-LSP

Article Number 4263617
Edition 08/2023
Number of pages 24
Language en
PDF (5 MB)
Accessory

In suction mode (8)

Fittings (1)

Hoses / hose joints (7)

Installation/setup (1)

Pipe installation (2)

Pressurised expansion tanks (43)

Suction filter (4)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Commissioning
Commissioning RainSystem AF150/AF400
    
2219393

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

-NET-

Maintenance
Maintenance BASIC RainSystem AF150/AF400
    
2219533

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance COMFORT RainSystem AF150/AF400
    
2219495

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM RainSystem AF150/AF400
    
2219548

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

More suitable services

Service packages
Service Package L RainSystem AF150/AF400
    
2219703

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package L includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • Energy Solutions
  • WiloCare Premium
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Repairs
  • Extended Warranty
Service Package M RainSystem AF150/AF400
    
2219674

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package M includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • WiloCare Comfort
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Repairs
  • Extended Warranty
Supervision
Supervision RainSystem AF150/AF400
    
2219327

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation RainSystem AF150/AF400
    
2219362

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation RainSystem AF150/AF400
    
2219257

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions RainSystem AF150/AF400
    
2219292

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair RainSystem AF150/AF400
    
2219616

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report