Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
RainSystem AF 150-2 Medana LSP405/RCP | Wilo
Similar to figure

RainSystem AF 150-2 Medana LSP405/RCP

Article number: 4254822
Technical data
Hydraulic data
Maximum operating pressure PN 8 bar
Discharge port G 1¼
Max. volume flow Qmax 6.4 m³/h
Optimal volume flow Qopt 3.8 m³/h
Max. delivery head Hmax 52.6 m
Optimal delivery head Hopt 35.8 m
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 1~230 V, 50 Hz
Shaft power P2(Q=max.) of selected impeller * number of pumps NO VALUE 750 W
Rated speed n 2900 1/min
Rated current IN 4.6 A
Power factor cos φ100 0.99
Protection class motor IP55
Insulation class F
Materials
Pump housing Stainless steel
Impeller PPE/PS-GF30
Shaft Stainless steel
Shaft seal BQ1EGG
Installation dimensions
Gross volume of the tank V 150 l
Gross volume of the diaphragm expansion tank V 8 l
Pipe connection on the suction side DNs G 1¼
Pipe connection on the discharge side DNd G 1¼

RainSystem AF 150

I Level sensor
Product data
Brand Wilo
Product description RainSystem AF 150-2 Medana LSP405/RCP
Article number 4254822
EAN number 4062679370545
Colour Green/black/silver
Minimum order quantity 1
Date of sales availability 2024-01-15
Successor model article number 4254795
Successor model designation RAINSYSTEM AF150-2Medana LSP405/EC
Packaging
Packaging type One-way pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1200 mm
Length L 870 mm
Height with packaging 1500 mm
Height H 1340 mm
Width with packaging 800 mm
Width W 750 mm
Gross weight, approx. m 105 kg
Net weight, approx. m 83 kg
Tender text

Automatic rainwater supply and fresh water replenishment system as a compact module for multi-residential and public buildings made up of two quiet, self-priming, multistage, horizontal, high-pressure centrifugal pumps with an innovative hydraulic suction passage. Ball valves on the suction and discharge sides for each pump with manifold on the discharge side. Replenishment reservoir (150 l) with demand-oriented replenishment of fresh water when rainwater storage tank is empty. Throughflow diaphragm expansion tank (8 l) conforming to DIN 4807 for energy savings in the event of very small leaks on the building side. All parts that come into contact with the fluid are corrosion-proof.

Electronic control

RainControl Professional with steady system control by means of cyclical pump cycling and integrated test run for idle pumps. Automatic fault-actuated switchover and peak-load cut-in ensure the highest degree of system availability. Water exchange for the replenishment reservoir depending on pump operation, calcination protection of the solenoid valve, integrated electronic motor protection and dry-running protection for the pumps, fill-level indicator, connection for backflow warning, includes user-friendly, menu-prompted operation and display on LCD display. Comprehensive notifications in the control device as well as potential-free contacts for collective run and fault signals. Ideal for connection to the building management system (BMS/DDC). Electrically and hydraulically connected and ready to be hooked up; mounted on grid pipe frame painted to protect against corrosion.

Optional:

Individual operation and individual fault signals, backflow signal

Materials
Pump housing Stainless steel
Shaft Stainless steel
Impeller PPE/PS-GF30
Operating Data
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Maximum operating pressure p 10.0 bar
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 1~230 V, 50 Hz
Rated speed n 2900 1/min
Rated current IN 4.6 A
Power factor cos φ100 0.99
Protection class motor IP55
Insulation class F
Installation dimensions
Overflow connection Ø110-PN0
Pipe connection on the suction side DNs G 1¼
Pipe connection on the discharge side DNd G 1¼
Ordering information
Net weight, approx. m 83 kg
Brand Wilo
Product description RainSystem AF 150-2 Medana LSP405/RCP
Article number 4254822
Documents

Installation and operating instructions

Wilo-Medana CH1-LSP

Article Number 4263617
Edition 08/2023
Number of pages 24
Language en
PDF (5 MB)
Accessory

In suction mode (8)

Fittings (1)

Hoses / hose joints (7)

Installation/setup (1)

Pipe installation (2)

Pressurised expansion tanks (43)

Suction filter (4)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Commissioning
Commissioning RainSystem AF150/AF400
    
2219393

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

-NET-

Maintenance
Maintenance BASIC RainSystem AF150/AF400
    
2219533

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance COMFORT RainSystem AF150/AF400
    
2219495

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM RainSystem AF150/AF400
    
2219548

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

More suitable services

Service packages
Service Package L RainSystem AF150/AF400
    
2219703

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package L includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • Energy Solutions
  • WiloCare Premium
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Repairs
  • Extended Warranty
Service Package M RainSystem AF150/AF400
    
2219674

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package M includes:

  • Installation check
  • Supervision
  • Commissioning
  • Maintenance
  • WiloCare Comfort
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Repairs
  • Extended Warranty
Service Package S RainSystem AF150/AF400
    
2219645

The Wilo service offers predefined service packages in three sizes to make it easier to combine individual services.

The Wilo-Service package S includes:

  • Installation check
  • Commissioning
  • Maintenance
  • WiloCare Basic
  • Wilo-Live Assistant

Optional add-on services:

  • System Optimisation
  • Energy Solutions
  • Supervision
  • Repairs
  • Extended Warranty
Supervision
Supervision RainSystem AF150/AF400
    
2219327

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation RainSystem AF150/AF400
    
2219362

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation RainSystem AF150/AF400
    
2219257

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions RainSystem AF150/AF400
    
2219292

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair RainSystem AF150/AF400
    
2219616

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report