P160
Caractéristiques techniques | |
---|---|
Alimentation réseau | 1~230 V, 50 Hz |
Puissance nominale P2 P2 | 500 W |
Commande | sans convertisseur de fréquence |
Type de branchement | Direct en ligne (DOL) |
Compatibilité électromagnétique | EN 61000 |
Norme de raccordement | EN 1254 |
Installation | Montage au sol |
Données d'exploitation | |
---|---|
Pression d'entrée max. | 8 bar |
Dimensions | |
---|---|
Dimensions H1 | 775,0 mm |
Dimensions H2 | 730,0 mm |
Dimensions H3 | 225,0 mm |
Dimensions H4 | 545,0 mm |
Dimensions H5 | 590,0 mm |
Dimensions L | 455,0 mm |
Pressurisation Unit Wiring Diagram
Données de produit | |
---|---|
Fabricant | Wilo |
Désignation du produit | P160 |
Référence | 2819493 |
Numéro EAN | 5013608000599 |
Couleur | vert/argent/gris |
Quantité minimum de commande | 1 |
Disponibilité sur le marché | 2012-06-01 |
Emballage | |
---|---|
Type d'emballage | Europalette |
Propriété de l'emballage | Emballage de transport |
Nombre par palette | 4 |
Quantité par layer | 4 |
Dimensions et poids | |
---|---|
Longueur avec emballage | 1000 mm |
Longueur L | 455 mm |
Hauteur avec emballage | 925 mm |
Hauteur H | 775 mm |
Largeur avec emballage | 800 mm |
Largeur W | 350 mm |
Poids brut m | 43 kg |
Poids net m | 28 kg |
The Wilo Comfort single pump pressurisation units are designed for use on heating or chilled water systems up to and including 3.5, 6.0 and 8.0 bar cold fill pressures.
The unit is fitted with an 18 litre polypropylene break tank c/w type AB air gap to BS13077:2008 and water regulations 1999, Wras approved equilibrium ball float valve to BS1212 and a low water float switch and strainers for pump protection.
Each pump is fitted with a non return valve and quick release couplings for ease of maintenance. The pressure transducer monitors the system pressure and feeds a 0-10v signal to the comfort controller.
Comfort Controller is complete with the following features:
- User friendly interface that has a 2 line LCD backlight display
- Healthy / fail LED
- Password protection
- System Fill for initial fill of system
- Pump check routine, that runs the pump for 2 seconds if inactive for 7-90 days
- Pump trip and fail alarms
- System leak alarm
- Excessive starts alarm
- Alarm log
- Hours Run
- Connectivity: BACnet = RS485 interface, BACnet MS/TP protocol
2 wire BACnet
Volt Free Contacts are supplied with terminals for common, normally open and normally closed.
(5A, 230V)
Pump no.1 trip, Pump no. 1 run, High Pressure, Low Pressure, Excess starts, Low water and Boiler Interlock (NC only)
(10A, 230V)
To be selected from Power fail, Common alarm, Common pressure alarm
Standards Applied:
Low Voltage and Machinery Directive 2006/42/EC, EMC Directive EMC 2004/108/EC, BSEN809, BS7074-1 to 3, BS13077:2008 and water regulations 1999.
Caractéristiques techniques | |
---|---|
Alimentation réseau | 1~230 V, 50 Hz |
Commande | sans convertisseur de fréquence |
Données d'exploitation | |
---|---|
Pression d'entrée max. | 8 bar |
Informations sur les passations de commande | |
---|---|
Largeur W | 350 mm |