Product design type | Glandless standard high-efficiency pump | Glandless high-efficiency pump | Glandless standard high-efficiency pump | Glandless premium smart-pump | Existing pump |
| | | | | |
| | | | | |
| | | | | |
Description | |
Product description | Yonos PICO 25/1-6 | Stratos PICO 25/0,5-6 | Yonos MAXO 40/0,5-4 PN 6/10 | Stratos MAXO 40/0,5-4 PN6/10 | TOP-D 40 (3~400 V, PN6/10) |
Article number | 4215515 | 4244395 | 2120645 | 2164582 | 2024109 |
Series | Wilo-Yonos PICO | Wilo-Stratos PICO | Wilo-Yonos MAXO | Wilo-Stratos MAXO | - |
Mains connection | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | 1~230 V ±10%, 50/60 Hz | - |
Port-to-port length | 180 mm | 180 mm | 220 mm | 220 mm | 220 mm |
Pump connection | G 1½ | G 1½ | DN 40 | DN 40 | - |
Pump connection (alternative designation) | RP 1 | RP 1 | - | - | - |
| DN 25 | DN 25 | - | - | - |
Display | LED segment display | Graphic colour display (2 inches) | LED segment display | Graphic colour display (4.3 inches) | - |
Comment | Works with other accessories without the need to change any piping
Check electrical connection | Works with other accessories without the need to change any piping
Check electrical connection | Fits without modifications
Check electrical connection | Fits without modifications
Check electrical connection | - |
Fitting piece (PN6) | 2 x 110679395 Flanged ring RF 9, PN6 | 2 x 110679395 Flanged ring RF 9, PN6 | - | - | - |
Function | |
Control mode | Δp-v for variable differential pressure | Δp-v for variable differential pressure | Δp-v for variable differential pressure | Δp-v for variable differential pressure | - |
| Δp-c for constant differential pressure | Δp-c for constant differential pressure | Δp-c for constant differential pressure | Δp-c for constant differential pressure | - |
| Constant speed (3 speed stages) | - | Constant speed (3 speed stages) | - | - |
| - | Dynamic Adapt plus | - | Dynamic Adapt plus | - |
| - | Constant speed (n-const.) | - | Constant speed (n-const.) | - |
| - | - | - | Q limit for limiting the maximum volume flow | - |
| - | - | - | ΔT-const. for constant differential temperature control | - |
| - | - | - | T-const. for constant temperature control | - |
| - | - | - | Constant Q for constant volume flow control | - |
| - | - | - | Multi Flow Adaptation | - |
| - | - | - | Δ T-const. for constant differential temperature control | - |
| - | - | - | User-defined PID control | - |
Special features of the series | - | Night set back | - | Night set back | - |
| - | Mode for pressure-independent control valves (PICV) | - | - | - |
| - | Key locking function | - | Key locking function | - |
| - | Reset function for electricity meter | - | - | - |
| - | Reset function to factory setting | - | Reset function to factory setting | - |
| - | - | - | Heating/Cooling switching | - |
| - | - | - | Heat quantity measurement | - |
| - | - | - | Cooling quantity measurement | - |
| - | - | - | No-Flow Stop | - |
| - | - | - | Adjustable volume flow limiter | - |
| - | - | - | Ability to save and restore configured pump settings (3 restoration points) | - |
| - | - | - | Fault message and warning message in plain text including suggested remedy | - |
Multi pump operation | - | - | Main/Standby (with Connect Module Yonos MAXO) | - | - |
| - | - | - | Main/Standby | - |
| - | - | - | Parallel operation | - |
Measurement value logging | - | - | - | Heat and cooling capacity measurement | - |
Display | Setpoint | Setpoint | Setpoint | Setpoint | - |
| Actual volume flow | Actual volume flow | - | Actual volume flow | - |
| Actual power consumption | Actual power consumption | - | Actual power consumption | - |
| Fault signals (error codes) | - | Fault signals (error codes) | - | - |
| Manually activated restart or pump venting function | Manually activated restart or pump venting function | - | - | - |
| - | Actual delivery head | - | Actual delivery head | - |
| - | Energy consumption | - | Energy consumption | - |
| - | Actual speed | - | - | - |
| - | Warning messages in plain text (display status: yellow) | - | Warning messages in plain text (display status: yellow) | - |
| - | Error messages in plain text (display: red) | - | Error messages in plain text (display: red) | - |
| - | Control mode | - | Control mode | - |
| - | Active influences (e.g. STOP) | - | Active influences (e.g. STOP) | - |
| - | - | - | Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - |
| - | - | - | Pump venting (display status: blue) | - |
Display (can also be selected) | - | - | - | Speed | - |
| - | - | - | Heating quantity | - |
| - | - | - | Cooling quantity | - |
| - | - | - | Operating hours | - |
| - | - | - | Mains voltage | - |
| - | - | - | Warning message | - |
| - | - | - | Error message | - |
Pump venting function | Manual | Manual | - | Yes | - |
Dry-running detection | - | yes | - | yes | - |
Equipment | |
Thermal insulation shell | As accessory | Yes | As accessory | Yes | - |
Cold water insulation shell | - | - | - | As accessories | - |
Quick electrical connection | Wilo Connector | Wilo Connector | Wilo plug | Wilo Connector | - |
Blocking-current proof motor | yes | yes | yes | yes | - |
Particle filter | yes | yes | yes | yes | - |
Key lock | - | yes | - | yes | - |
Operating elements | Green button | Green button and back button | - | - | - |
Fluid temperature sensor | - | - | - | Integrated | - |
Connectivity | |
Analogue signal as standard | - | 0-10 V (via BMS Connect module accessories) | - | - | - |
| - | - | - | 0-10 V | - |
| - | - | - | 2-10 V | - |
| - | - | - | 4-20 mA | - |
| - | - | - | 0-20 mA | - |
| - | - | - | PT1000 | - |
Digital output | - | SSM/SBM (via BMS Connect module accessories) | - | - | - |
| - | - | SSM/SBM (via accessories Connect module Yonos MAXO) | - | - |
| - | - | - | SSM | - |
| - | - | - | SBM | - |
Digital input | - | Ext. OFF/Ext. MIN/ Ext. MAX (via BMS Connect module accessories) | - | - | - |
| - | - | Ext. OFF (via accessories Wilo-Connect module Yonos MAXO) | - | - |
| - | - | - | Ext. OFF | - |
| - | - | - | Ext. MIN | - |
| - | - | - | Ext. MAX | - |
| - | - | - | MANUAL (BMS-OFF) | - |
| - | - | - | Key lock | - |
| - | - | - | Switchover between heating/cooling mode | - |
Bus communication via additional accessories | - | - | - | BACnet MS/TP | - |
| - | - | - | LON | - |
| - | - | - | Modbus RTU | - |
| - | - | - | CANopen | - |
| - | - | - | PLR | - |
| - | - | - | BACnet IP | - |
| - | - | - | Modbus TCP | - |
Access via the Wilo-Assistant app | - | Via accessory Wilo-Smart Connect Module BT | - | Yes | - |
Connection for Wilo-Smart Cloud | - | - | - | Via Wilo-Smart Gateway | - |
wire data exchange and remote operation | - | Via accessories Wilo-Smart Connect Module BT | - | Bluetooth | - |
Motor data | |
Phases | 1 | 1 | 1 | 1 | 3 |
Mains connection | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 1~230 V, 50/60 Hz | 3~400 V, 50 Hz |
Energy efficiency index (EEI) %%fn=footnote%% | ≤0.20 | ≤0.18 | ≤0.20 | ≤0.19 | - |
Min current | - | - | 0.09 A | 0.11 A | - |
Max current | - | - | 1 A | 0.93 A | - |
Rated power | 30 W | 30 W | 90 W | 99 W | - |
Min. speed | 700 1/min | 700 1/min | 1200 1/min | 750 1/min | - |
Max. speed | 4200 1/min | 4200 1/min | 3700 1/min | 2600 1/min | - |
Power consumption | 4 W | 3 W | 7 W | 7 W | - |
Power consumption | 40 W | 40 W | 120 W | 130 W | - |
Emitted interference | EN 61000-6-3 | EN 61000-6-3 | EN 61800-3;2004+A1;2012 /residential area (C1) | EN 61800-3;2004+A1;2012 /residential area (C1) | - |
Interference resistance | EN 61000-6-2 | EN 61000-6-2 | EN 61800-3;2004+A1;2012 /industrial environment (C2) | EN 61800-3;2004+A1;2012 /industrial environment (C2) | - |
Electromagnetic compatibility | EN 61800-3 | EN 61800-3 | - | - | - |
Insulation class | F | F | F | F | - |
Protection class | IPX4D | IPX4D | IPX4D | IPX4D | - |
Sound-pressure level | - | - | - | 27 dB | - |
Materials | |
Bearing | Carbon, metal-impregnated | Carbon, metal-impregnated | Carbon-graphite | Carbon-graphite | - |
Pipe connection | |
Inlet connection | G 1½ | G 1½ | DN 40 | DN 40 | DN 40 |
PN connection on suction side | PN 10 | PN 10 | PN 6/10 | PN 6/10 | PN 6/10 |
Outlet connection | G 1½ | G 1½ | DN 40 | DN 40 | DN 40 |
PN connection on discharge side | PN 10 | PN 10 | PN 6/10 | PN 6/10 | PN 6/10 |
Dimension, weight | |
Length with packaging | 194 mm | 194 mm | 400 mm | 600 mm | - |
Length | 180 mm | 180 mm | 223 mm | 355 mm | - |
Height with packaging | 105 mm | 121 mm | 395 mm | 394 mm | - |
Height | 102 mm | 114 mm | 240 mm | 220 mm | - |
Width with packaging | 174 mm | 213 mm | 300 mm | 400 mm | - |
Width | 131 mm | 165 mm | 150 mm | 227 mm | - |
Gross weight, approx. | 2 kg | 2.2 kg | 10.2 kg | 14.8 kg | - |
Net weight, approx. | 1.8 kg | 1.9 kg | 8.6 kg | 11.4 kg | 9.5 kg |
Ordering information | |
Product description | Yonos PICO 25/1-6 | Stratos PICO 25/0,5-6 | Yonos MAXO 40/0,5-4 PN 6/10 | Stratos MAXO 40/0,5-4 PN6/10 | TOP-D 40 (3~400 V, PN6/10) |
Brand | Wilo | Wilo | Wilo | Wilo | Wilo |
EAN number | 4048482758473 | 4062679126159 | 4048482235929 | 4048482699585 | - |
Article number | 4215515 | 4244395 | 2120645 | 2164582 | 2024109 |