Wilo-SiFire EN | Wilo
Your advantages
Wilo-SiFire EN

Your advantages

  • Pressure-loss optimised system designed in accordance with the EN 12845 Standard with electrical or diesel drive, jockey pump for maintaining system pressure
  • Flexible, modular and solid construction for safe transport and simple installation
  • Bypass volume flow for the protection of the pump with spacer coupling for simple maintenance
  • High-quality SC-Fire control prepared for BACnet and Modbus building management system integration
  • Special baseplate for minimal vibrations, cable laid in the construction in such a way as to ensure maximum reliability and service life

Series description
SiFire EN

Design

Pressure-boosting systems for firefighting according to EN 12845. Consists of 1 or 2 pumps, depending on the module, with horizontal baseplate - EN 733 - with spacer coupling, electric or diesel motor and a multistage, vertical electric jockey pump.

Application

Fully automatic water supply of fire-fighting systems with a sprinkler system in residential, commercial, public and industrial buildings, as well as hotels, hospitals and department stores.

Equipment/function

  • One or two pumps with a horizontal base frame from the series 32-200 to 150-315, with an IE-equivalent standard motor or diesel motor
  • With a diaphragm installed directly on the main pump housing to prevent overheating in the event of zero flow
  • Jockey pump of Medana CV1-L series with pressure switch and vertical pressure tank 20 l, PN 16
  • One switch cabinet per pump, fixed to a robust support structure. SC Fire model: E for the electric motor and D for the diesel motor, both equipped with Smart Controller, plus J for the jockey pump
  • Base frame made of electro-galvanised steel with height-adjustable holder for the outlet manifold
  • Pipework made of steel; painted with epoxy resin. Manifold with flanges
  • Shutting gate with safety lock on the discharge side of each pump
  • Swing check valve on the discharge side of each pump
  • A circuit with dual pressure switch, pressure gauge, swing check valve, valve for the main pump and standby pump for automatic start
  • Concentric cone on the discharge side of the main and standby pump, for speed limitation according to the parameters specified in EN 12845
  • DN 2" connection for the supply tank of the pumps
  • Pressure measurement on the discharge side
  • Only for the model with diesel motor:
    • Vibration damping sleeve on the discharge side of the pump
    • Vibration damper under the base frame of the pump
    • Fuel tank with level sensor and sufficient volume for six hours of autonomous operation
    • 2 or 4 batteries on the base frame and battery charger at the SC Fire switch cabinet
  • Accessories upon request: Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Horizontal 500 l supply tank, with float valve and pressure switch for LL-alarm (water shortage)
    • Flow meter: Kit with eccentric cone on the suction side, complete with butterfly valve with hand lever or handwheel
    • Vacuum gauge with valve
    • Valves with electrical contact
    • Vibration damping sleeve for the manifold
    • Remote control panel for transmitting level A and level B alarms
    • Density meter for battery
    • Spare parts kit for the diesel motor
    • Silencer (30 dBA) for the diesel motor
    • Hydraulic heat exchanger for the diesel motor

Typekey

Example:

Wilo-SiFire EN 40/200-180-7.5/10.5/0.55 EDJ

SiFire

Compact pressure boosting system for fire fighting equipment

EN

in acc. with EN 12845

40/200

Type of main pump

180

Actual impeller diameter of the main pump

7.5

Power of the electric motor [kW]

10.5

Power of the diesel motor [kW]

00:55

Power of the motor for the jockey pump [kW]

EDJ

Configuration

E

An electric pump

D

A diesel pump

J

A jockey pump

Technical data

  • Mains connection 3~400 V, 50 Hz (1~230 V, 50 Hz for the control panel of the diesel pump)
  • IE-equivalent standard motors, diesel motor with direct injection or turbo diesel motor with air or water cooling
  • Max. ambient temperature +4°C to +40°C (+10°C to +40°C, if a diesel pump is installed)
  • Max. fluid temperature +40°C
  • Max. operating pressure 10 or 16 bar
  • Max. inlet pressure 6 bar
  • Volume flow 10 m³/h to 750 m³/h
  • Max. delivery head 128 m
  • Nominal connection diameters on the pressure side DN 65 to DN 250
  • Nominal connection diameters on the intake side DN 50 to DN 200
  • Switch cabinet protection class IP54
  • Main/standby pump with horizontal base plate in accordance with EN 733
  • With epoxy resin painted piping and hydraulic connections
  • Permitted fluids:Note on fluids: Approved fluids are generally waters which do not attack the materials used, neither chemically nor mechanically, and do not contain any abrasive or long-fibre constituents. System in accordance with EN 12845
    • Non-aggressive, clean water
    • Fire water

Materials

For the pump with a horizontal base frame, depending on the model

  • Impellers made of bronze CuSn10 or CuAl10Fe5Ni5 or stainless steel AISI 316/ 1.4401
  • Pump housing made of grey cast iron EN-GJL-250
  • Shaft made of stainless steel AISI420/1.4021 or AISI 431/ 1.4057
  • Neck rings made of stainless steel AISI316L/1.4409 or bronze

For the jockey pump

  • Impellers made of stainless steel AISI 304/ 1.4301
  • Pump housing made of stainless steel AISI304/1.4301
  • Shaft made of stainless steel AISI 304/ 1.4301
  • O-ring seals made of EPDM

Construction

  • Base frame: Manufactured from profiles consisting of electro-galvanised steel with brackets for the switch cabinets and the outlet manifold. Special square holes at the bottom for forklift trucks, as well as integrated hooks for lifting slings. Side profiles at the top on each side to enhance the rigidity of the system when moving and lifting.
  • Plastic cover at the rear which provides visual access to the valve position and pressure gauge.
  • Pipework: Complete pipework with flanges made of epoxy resin painted steel, suitable for the connection of all common piping materials; the dimensions of the pipework must correspond to the overall hydraulic performance of the pressure boosting system
  • Pumps: 1 or 2 pumps with horizontal base frame - EN 733 - with spacer coupling, electric or diesel motor.
  • • Back-pull-out model to ensure the internal parts of the pump are easy to access without having to move the motor or piping.
  • Valves: The main pumps are fitted with a shut-off valve and non-return valve on the discharge side, both of which are painted with epoxy resin and adapted for a flange connection.
  • Diaphragm pressure vessel: Diaphragm pressure vessel 20 l/PN16, on the discharge side of the jockey pump, with drain plug.
  • Tank: The fuel tank is made of metal painted with epoxy resin and is located behind the bracket of the switch cabinet
  • Sensors and display: 2 pressure switches, 2/16 bar per pump, on the discharge side, for activating the pump start via the SCFire controller and regulator. The discharge side pressure gauge (∅ 63 mm) is located in the middle of the rear panel.
  • Controller: The system is equipped as standard with a separate switchgear/control device (SC Fire) for the electric or diesel motor and a switchgear/control device for the jockey pump.

Scope of delivery

  • Factory-mounted, ready-for-installation pressure boosting system, which has been checked for functionality and impermeability
  • Installation and operating instructions
  • Required accessories on request

Consulting guide

Inlet pressure

The maximum inlet pressure must be taken into account when designing the system configuration (see Technical data). The maximum permissible inlet pressure is calculated from the maximum operating pressure of the system minus the maximum delivery head of the pump at Q = 0. For sprinkler systems in accordance with EN 12845, the water pressure should not exceed 12 bar. In sprinkler systems with a pronounced slope, in which the difference in height between the highest and lowest sprinkler is more than 45 m, the water pressure can be higher than 12 bar at the pump outlet or in the piping, provided that all of the system components are designed for this pressure level.

Installation of the pressure boosting pump under suction conditions.

For each main pump, it is necessary to install a supply tank with connection to the discharge pipe above the pump.

Volume flow

Up to 750 m³/h (208 l/s) system configuration for each main pump.

Operation

The operating logic for the fire extinguishing unit is based on the cascade calibration of the pressure switches for starting the pump.

The jockey pump is started and stopped automatically by a pressure switch. It is designed in such a way that not only individual sprinklers are supplied with fluid and pressure, but the entire system. This ensures the main pump is prevented from being started and that the system remains pressurised. If a lower pressure value is caused by the demand for water, which is not compensated by the jockey pump, the main and standby pump are started one after the other. The system starts automatically, it can be stopped manually using the switch on the front of the control panel.

Documents

Installation and operating instructions

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 13
Language en
PDF (934 KB)

Wilo-Control SC-Fire Diesel

Article Number 2541367
Edition 1510
Number of pages 34
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 32
Language en
PDF (2 MB)

Wilo-Control SC-Fire Jockey

Number of pages 10
Language en
PDF (727 KB)

Wilo-SiFire EN

Article Number 4188030
Edition 2019-12
Number of pages 108
Language de, en, fr, nl
PDF (9 MB)

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 148
Language en, mk, no, sr, uk
PDF (6 MB)

Wilo-MVIL

Article Number 4086201
Edition 1502
Number of pages 13
Language en
PDF (1 MB)

Wilo-Control SC-Fire Electric

Article Number 2539954, 2541365, 2541366
Edition 1510
Number of pages 31
Language en
PDF (1 MB)

Wilo-Priming tank 500 L

Article Number 4228982
Edition 2019-05
Number of pages 451
Language ar, bg, cs, da, de, el, en, es, et, fi, fr, hr, hu, it, lt, lv, nl, no, pl, pt, ro, ru, sk, sl, sr, sv, tr, uk
PDF (18 MB)
Product selection
Number of results: 433
29 … 756 m³/h
[433]
Product descriptionSystem output without standby pump QMaximum operating pressure PNGross weight, approx. mArticle number
SiFire-EN-80/250-235-55E
227 m³/h
16 bar
1272 kg
4241432
SiFire-EN-80/250-235-55EJ
227 m³/h
16 bar
1316 kg
4241507
SiFire-EN-80/250-235-66D
227 m³/h
16 bar
700 kg
4241582
SiFire-EN-80/250-235-66DJ
227 m³/h
16 bar
829 kg
4241657
SiFire-EN-80/250-243-66D
233 m³/h
16 bar
830 kg
4241583
SiFire-EN-80/250-243-66DJ
233 m³/h
16 bar
959 kg
4241658
SiFire-EN-80/250-243-75E
233 m³/h
16 bar
1311 kg
4241433
SiFire-EN-80/250-243-75EJ
233 m³/h
16 bar
1355 kg
4241508
SiFire-EN-80/250-254-75E
232 m³/h
16 bar
1523 kg
4241434
SiFire-EN-80/250-254-75EJ
232 m³/h
16 bar
1567 kg
4241509
SiFire-EN-80/250-254-100D
232 m³/h
16 bar
866 kg
4241584
SiFire-EN-80/250-254-100DJ
232 m³/h
16 bar
995 kg
4241659
SiFire-EN-80/250-270-90E
232 m³/h
16 bar
1559 kg
4241435
SiFire-EN-80/250-270-90EJ
232 m³/h
16 bar
1603 kg
4241510
SiFire-EN-80/250-270-100D
232 m³/h
16 bar
866 kg
4241585
SiFire-EN-80/250-270-100DJ
232 m³/h
16 bar
995 kg
4241660
SiFire-EN-80/315-275-90E
225 m³/h
16 bar
1272 kg
4241436
SiFire-EN-80/315-275-90EJ
225 m³/h
16 bar
1316 kg
4241511
SiFire-EN-80/315-275-100D
225 m³/h
16 bar
900 kg
4241586
SiFire-EN-80/315-275-100DJ
225 m³/h
16 bar
1029 kg
4241661
SiFire-EN-80/315-290-109D
216 m³/h
16 bar
914 kg
4241587
SiFire-EN-80/315-290-109DJ
216 m³/h
16 bar
1043 kg
4241662
SiFire-EN-80/315-290-110E
216 m³/h
16 bar
1272 kg
4241437
SiFire-EN-80/315-290-110EJ
216 m³/h
16 bar
1316 kg
4241512
SiFire-EN-80/315-308-132E
219 m³/h
16 bar
1311 kg
4241438
SiFire-EN-80/315-308-132EJ
219 m³/h
16 bar
1355 kg
4241513
SiFire-EN-80/315-308-145D
219 m³/h
16 bar
1083 kg
4241588
SiFire-EN-80/315-308-145DJ
219 m³/h
16 bar
1212 kg
4241663
SiFire-EN-80/315-318-145D
221 m³/h
16 bar
1083 kg
4241589
SiFire-EN-80/315-318-145DJ
221 m³/h
16 bar
1212 kg
4241664
SiFire-EN-80/315-318-160E
221 m³/h
16 bar
1523 kg
4241439
SiFire-EN-80/315-318-160EJ
221 m³/h
16 bar
1567 kg
4241514
SiFire-EN-80/315-324-160E
223 m³/h
16 bar
1559 kg
4241440
SiFire-EN-80/315-324-160EJ
223 m³/h
16 bar
1603 kg
4241515
SiFire-EN-80/315-324-197D
223 m³/h
16 bar
1103 kg
4241590
SiFire-EN-80/315-324-197DJ
223 m³/h
16 bar
1232 kg
4241665
SiFire-EN-100/200-168R-22/22EEJ
354 m³/h
10 bar
1040 kg
4183974
SiFire-EN-100/200-183-30/30EEJ
359 m³/h
10 bar
1284 kg
4183975
SiFire-EN-100/200-183-30/31,5EDJ
359 m³/h
10 bar
1633 kg
4184044
SiFire-EN-100/200-183-30EJ
359 m³/h
10 bar
825 kg
4183768
SiFire-EN-100/200-183-31,5D
359 m³/h
10 bar
850 kg
4183837
SiFire-EN-100/200-194-37/47,7EDJ
366 m³/h
10 bar
1727 kg
4184045
SiFire-EN-100/200-205-45/45EEJ
377 m³/h
10 bar
1567 kg
4183977
SiFire-EN-100/200-205-45/47,7EDJ
377 m³/h
10 bar
1849 kg
4184046
SiFire-EN-100/200-205-47,7DJ
377 m³/h
10 bar
933 kg
4183908
SiFire-EN-100/200-212-45/45EEJ
250 m³/h
16 bar
1762 kg
4241729
SiFire-EN-100/200-212-45/47,7EDJ
250 m³/h
16 bar
2050 kg
4241779
SiFire-EN-100/200-212-45E
250 m³/h
16 bar
1559 kg
4241441
SiFire-EN-100/200-212-45EJ
250 m³/h
16 bar
1603 kg
4241516
SiFire-EN-100/200-212-47,7D
250 m³/h
16 bar
1122 kg
4241591