Product design type | Glandless premium smart twin-head pump | Glanded energy-saving twin-head pump | Glandless standard high-efficiency pump | Existing pump |
| | | | |
| | | | |
| | | | |
Description | |
Product description | Stratos MAXO-D 80/0,5-12 PN 10 | Yonos GIGA2.0-D 80/1-10/2,2 | Yonos MAXO-D 80/0,5-12 PN 10 | 102/4175 |
Article number | 2164663 | 2205897 | 2120673 | - |
Series | Wilo-Stratos MAXO-D | Wilo-Yonos GIGA2.0-D | Wilo-Yonos MAXO-D | - |
Mains connection | 1~230 V ±10%, 50/60 Hz | - | 1~230 V ±10%, 50/60 Hz | - |
| - | 3~380 V ±10%, 50/60 Hz | - | - |
| - | 3~400 V ±10%, 50/60 Hz | - | - |
| - | 3~440 V ±10%, 50/60 Hz | - | - |
Port-to-port length l0 | 360 mm | 360 mm | 360 mm | 500 mm |
Pump connection | DN 80 | DN 80 | DN 80 | - |
Display | Graphic colour display (4.3 inches) | Graphic colour display (2 inches) | LED segment display | - |
Comment | Change piping
Check electrical connection | Change piping | Change piping
Check electrical connection | - |
Result summary | |
Function | |
Control mode | Δp-v for variable differential pressure | Δp-v for variable differential pressure | Δp-v for variable differential pressure | - |
| Δp-c for constant differential pressure | Δp-c for constant differential pressure | Δp-c for constant differential pressure | - |
| Q limit for limiting the maximum volume flow | - | - | - |
| Dynamic Adapt plus | - | - | - |
| ΔT-const. for constant differential temperature control | - | - | - |
| T-const. for constant temperature control | - | - | - |
| Constant Q for constant volume flow control | - | - | - |
| Multi Flow Adaptation | - | - | - |
| Δ T-const. for constant differential temperature control | - | - | - |
| User-defined PID control | User-defined PID control | - | - |
| Constant speed (n-const.) | Constant speed (n-const.) | - | - |
| - | - | Constant speed (3 speed stages) | - |
Special features of the series | Heating/Cooling switching | - | - | - |
| Night set back | - | - | - |
| Heat quantity measurement | - | - | - |
| Cooling quantity measurement | - | - | - |
| Key locking function | - | - | - |
| No-Flow Stop | - | - | - |
| Reset function to factory setting | - | - | - |
| Adjustable volume flow limiter | - | - | - |
| Ability to save and restore configured pump settings (3 restoration points) | - | - | - |
| Fault message and warning message in plain text including suggested remedy | - | - | - |
Multi pump operation | Main/Standby | Main/Standby | Main/Standby | - |
| Parallel operation | Parallel operation | - | - |
Measurement value logging | Heat and cooling capacity measurement | - | - | - |
Display | Setpoint | - | Setpoint | - |
| Actual delivery head | Actual delivery head | - | - |
| Actual volume flow | Actual volume flow | - | - |
| Actual power consumption | Actual power consumption | - | - |
| Energy consumption | Energy consumption | - | - |
| Temperature (version “-R7”: current fluid temperature possible with Stratos MAXO temperature sensor) | - | - | - |
| Warning messages in plain text (display status: yellow) | Warning messages in plain text (display status: yellow) | - | - |
| Error messages in plain text (display: red) | Error messages in plain text (display: red) | - | - |
| Pump venting (display status: blue) | - | - | - |
| Control mode | - | - | - |
| Active influences (e.g. STOP) | - | - | - |
| - | Current operating status and data, as well as faults | - | - |
Display (can also be selected) | Speed | - | - | - |
| Heating quantity | - | - | - |
| Cooling quantity | - | - | - |
| Operating hours | - | - | - |
| Mains voltage | - | - | - |
| Warning message | - | - | - |
| Error message | - | - | - |
Pump venting function | Yes | - | - | - |
Dry-running detection | yes | - | - | - |
Equipment | |
Cable glands for sensors and communication | - | Mains connection | - | - |
| - | Communication | - | - |
Thermal insulation shell | No | - | - | - |
Cold water insulation shell | No | - | - | - |
Quick electrical connection | Wilo Connector | - | Wilo plug | - |
Blocking-current proof motor | yes | - | - | - |
Particle filter | yes | - | - | - |
Key lock | yes | - | - | - |
Fluid temperature sensor | Integrated | - | - | - |
Connectivity | |
Analogue signal as standard | 0-10 V | 0-10 V | - | - |
| 2-10 V | 2-10 V | - | - |
| 4-20 mA | 4-20 mA | - | - |
| 0-20 mA | 0-20 mA | - | - |
| PT1000 | - | - | - |
Digital output | SSM | - | SSM | - |
| SBM | - | - | - |
| - | SSM or SBM | - | - |
| - | - | SBM (via Connect module) | - |
Digital input | Ext. OFF | Ext. OFF | - | - |
| Ext. MIN | - | - | - |
| Ext. MAX | - | - | - |
| MANUAL (BMS-OFF) | - | - | - |
| Key lock | - | - | - |
| Switchover between heating/cooling mode | - | - | - |
| - | - | Ext. OFF (via accessories Wilo-Connect module Yonos MAXO) | - |
Bus communication via additional accessories | BACnet MS/TP | BACnet MS/TP | - | - |
| LON | LON | - | - |
| Modbus RTU | Modbus RTU | - | - |
| CANopen | CANopen | - | - |
| PLR | PLR | - | - |
| BACnet IP | - | - | - |
| Modbus TCP | - | - | - |
| - | Ethernet | - | - |
Access via the Wilo-Assistant app | Yes | - | - | - |
Connection for Wilo-Smart Cloud | Via Wilo-Smart Gateway | - | - | - |
wire data exchange and remote operation | Bluetooth | - | - | - |
Motor data | |
Phases | 1 | 3 | 1 | 3 |
Mains connection | 1~230 V, 50/60 Hz | 3~400 V, 50/60 Hz | 1~230 V, 50/60 Hz | 3~400 V, 50 Hz |
Energy efficiency index (EEI) | ≤0.17 | - | ≤0.23 | - |
Min current Imin | 0.3 A | - | 0.3 A | - |
Max current Imax | 6.13 A | - | 6.8 A | - |
Rated power P2 | 1212 W | 2200 W | 1300 W | - |
Min. speed nmin | 500 1/min | 500 1/min | 900 1/min | - |
Max. speed nmax | 3050 1/min | 2850 1/min | 3300 1/min | - |
Power consumption P1 min | 20 W | - | 40 W | - |
Power consumption P1 max | 1410 W | 2500 W | 1550 W | - |
Emitted interference | EN 61800-3;2004+A1;2012 /residential area (C1) | EN 61800-3 | EN 61800-3;2004+A1;2012 /residential area (C1) | - |
Interference resistance | EN 61800-3;2004+A1;2012 /industrial environment (C2) | EN 61800-3 | EN 61800-3;2004+A1;2012 /industrial environment (C2) | - |
Insulation class | F | F | F | - |
Protection class | IPX4D | IP55 | IPX4D | - |
Materials | |
Material | Grey cast iron | Grey cast iron | Grey cast iron | - |
Impeller | PPS-GF40 | PPE/PS-GF30 | PP-LGF50 | - |
Shaft | 1.4028, DLC-coated | Stainless steel | Stainless steel | - |
Bearing | Carbon, antimony-impregnated | - | Carbon, metal-impregnated | - |
Pipe connection | |
Inlet connection | DN 80 | DN 80 | DN 80 | - |
PN connection on suction side | PN 10 | PN 16 | PN 10 | - |
Outlet connection | DN 80 | DN 80 | DN 80 | DN 100 |
PN connection on discharge side | PN 10 | PN 16 | PN 10 | PN 6 |
Dimension, weight | |
Length with packaging | 800 mm | 1200 mm | 550 mm | - |
Length L | 360 mm | 533 mm | 360 mm | - |
Height with packaging | 525 mm | 800 mm | 425 mm | - |
Height H | 463 mm | 408 mm | 439 mm | - |
Width with packaging | 600 mm | 800 mm | 530 mm | - |
Width W | 570 mm | 601 mm | 424 mm | - |
Gross weight, approx. m | 70.5 kg | 125 kg | 60.6 kg | - |
Net weight, approx. m | 65.2 kg | 76 kg | 56.6 kg | - |
Ordering information | |
Product description | Stratos MAXO-D 80/0,5-12 PN 10 | Yonos GIGA2.0-D 80/1-10/2,2 | Yonos MAXO-D 80/0,5-12 PN 10 | 102/4175 |
Brand | Wilo | Wilo | Wilo | Vadstena |
EAN number | 4048482700052 | 4062679110240 | 4048482408033 | - |
Article number | 2164663 | 2205897 | 2120673 | - |