Article number: 2554534
Technical data
Hydraulic data
Maximum operating pressure PN 4 bar
Min. fluid temperature Tmin 3 °C
Max. fluid temperature Tmax 40 °C
Min. ambient temperature Tmin 3 °C
Max. ambient temperature Tmax 40 °C
Switching volume V 295 l
Macerator no
Motor data
Mains connection 3~400 V, 50 Hz
Rated current IN 25 A
Phase 3
Rated speed n 2910 1/min
Number of poles 2
Activation type Star-Delta (YΔ)
Max. switching frequency t 15 1/h
Power consumption P1(Q=max.) of selected impeller * number of pumps P1 15200 W
Motor efficiency class IE0
For Wilo pumps Rexa SUPRA-V08-974-175 + FK 202-2/17
Insulation class H
Protection class IP68
Materials
Pump housing Grey cast iron
Impeller Grey cast iron
Shaft Stainless steel
Motor housing Grey cast iron
Installation dimensions
Operating mode (non-immersed) S1
Pipe connection on the discharge side DN 80
Pipe connection on the suction side DN 200

Wilo-EMUport CORE 20.2

Product data
Brand Wilo
Product description EMUport CORE 20.2-40/540
Article number 2554534
EAN number 4062679160795
Colour black/silver
Minimum order quantity 1
Date of sales availability 2021-11-01
Packaging
Packaging type Euro pallet
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 1500 mm
Length L 1390 mm
Height with packaging 1580 mm
Height H 1430 mm
Width with packaging 1500 mm
Width W 1410 mm
Gross weight, approx. m 604 kg
Net weight, approx. m 554 kg
Tender text

Fully submersible sewage lifting unit, ready for connection, with solids separation according to DIN EN 12050-1. Due to the version as a solids separation system, the coarse solids are separated before the pumps and do not come into contact with the pumps. This ensures maximum operational reliability. All-in-one gas-tight and watertight collection reservoir without constructive welded joints, as well as two separately-lockable and externally maintainable solids separation reservoirs. Individual shut-off makes it possible to carry out maintenance work during operation. Pumping is performed by two high-performance submersible sewage pumps in dry well installation that run in alternating operation. The dry well installation of the pumps and their configuration as a redundant double-pump system ensures maximum hygiene, ease of maintenance, and operational reliability. The collection reservoir has rounded edges, the tank bottom is bevelled, the deepest point is located directly below the pump. This prevents deposits and the drying of solids at critical points. Quick connector to the pumps and the inspection opening facilitate maintenance work. Separate blocking of the solids separation reservoir facilitate maintenance while the unit is in operation. Manual backwashing in the collection reservoir reinforces the cleaning effect through additional turbulences and the transparent cover on the distributor box allows easy visual inspection of the unit. Level control is carried out using a level probe.

Scope of delivery

  • Submersible pump solids separation system with two dry well installation submersible pumps
  • 2x gate valve for solids separation reservoir
  • 2x non-return valve on the discharge side in rectangular design
  • 2x gate valve on the discharge side
  • Consolidation of the pressure outlet line
  • 1x level probe
  • 1x floor fixation as cross beam
  • 2.5 m ventilation and venting hose
  • 1x maintenance kit with blind flange

Recommended accessories

  • Wilo-Control SC-L-…-FTS switchgear
  • Inlet slide valve
  • Rinsing kit for supply box
Operating Data
For Wilo pumps Rexa SUPRA-V08-974-175 + FK 202-2/17
Approved field of application
Fluid temperature T 3 °C
Max. fluid temperature, for short periods up to 3 min. T 40 °C
Ambient temperature T 3 °C
Maximum operating pressure PN 4 bar
Max. permissible pressure in the pressure pipe P 6 bar
Product data
Gross volume of the tank V 440 l
Switching volume V 295 l
Operating mode (non-immersed) S1
Height H 1430 mm
Length L 1390 mm
Width W 1410 mm
Diagonal dimension Diagonal axis 1500 mm
Motor data
Mains connection 3~400 V, 50 Hz
Voltage tolerance ±10 %
Rated power P2 11.5 kW
Rated speed n 2910 1/min
Rated current IN 25 A
Insulation class H
Protection class motor IP68
Activation type Star-Delta (YΔ)
Max. switching frequency t 15 1/h
Motor protection Bimetall
Cable
Connection cable length L 20 m
Cable type NSSHÖU-J
Cable cross-section 2x 4x2,5 + 2x1,5 mm²
Mains plug no
Type of connection cable Non-detachable
Materials
Tank PE
Pump housing Grey cast iron
Impeller Grey cast iron
Shaft Stainless steel
Gasket material FKM
Motor housing Grey cast iron
Installation dimensions
Pipe connection on the suction side DN 200
Pipe connection on the discharge side DN 80
Connection venting Ø 75
Ordering information
Brand Wilo
Product description EMUport CORE 20.2-40/540
Net weight, approx. m 554 kg
Article number 2554534
Documents

Installation and operating instructions

Wilo-EMUport CORE

Article Number 6092612
Edition 2022-01
Number of pages 32
Language en
PDF (6 MB)

Wilo-Control SC-L...-FTS

Article Number 2545546
Edition 08-2016
Number of pages 112
Language de, en, es, fr, hu
PDF (13 MB)

Certification booklet

Wilo-EMUport Core 20.2 / 45.2 / 50.2 / 60.2

Article Number 2546469
Edition 2021-07
Number of pages 40
Language ar, az, ba, bg, cs, da, de, el, en, es, et, fi, fr, ga, hr, hu, it, ko, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sq, sr, sv, tr, uk, zh
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
BIM/CAD
Accessory

Level control with level sensor (3)

Stationary dry well installation (21)

Adapter (6)

Fittings (2)

Installation/setup (7)

Pipes/pipe joints (7)

Pump control/accessories (1)

Alarm signal (5)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance COMFORT EMUport Core
    
2219518

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during normal service hours)

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Maintenance PREMIUM EMUport Core
    
2219571

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Includes wearing parts

Scheduling and organisation is performed by WILO. Other individual maintenance offers are possible on request.

Commissioning
Commissioning EMUport Core
    
2219415

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

More suitable services

Extended Warranty
Extended Warranty EMUport Core
    
2219469

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service
Supervision
Supervision EMUport Core
    
2219352

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation EMUport Core
    
2219387

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation EMUport Core
    
2219282

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions EMUport Core
    
2219317

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair EMUport Core
    
2219636

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report