Search
Contact
E-mail
Catalogue creation
My favorites
Product comparison
Initial JET System 4-4-50 | Wilo

Initial JET System 4-4-50

Article number: 4168024
Technical data
Hydraulic data
Maximum operating pressure PN 6 bar
Discharge port G 1
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Min. ambient temperature Tmin 0 °C
Max. ambient temperature Tmax 40 °C
Motor data
Mains connection 1~230 V, 50 Hz
Voltage tolerance ±10 %
Shaft power P2(Q=max.) of selected impeller * number of pumps NO VALUE 750 W
Rated power P2 0.75 kW
Rated current IN 5 A
Rated speed n 2850 1/min
Insulation class F
Protection class IPX4
Materials
Pump housing Grey cast iron
Impeller Stainless steel
Shaft Steel
Shaft seal BQ1PFF
Gasket material NBR
Installation dimensions
Pipe connection on the suction side DNs G 1
Pipe connection on the discharge side DNd G 1

Wilo-INITIAL JET SYSTEM 4-4

Product data
Brand Wilo
Product description Initial JET System 4-4-50
Article number 4168024
EAN number 4048482250861
Colour green/black
Minimum order quantity 1
Date of sales availability 2019-03-01
Packaging
Packaging type Cardboard box
Packaging property Transport packaging
Pieces per pallet 1
Number per layer 1
Dimension, weight
Length with packaging 772 mm
Length L 640 mm
Height with packaging 704 mm
Height H 560 mm
Width with packaging 392 mm
Width W 380 mm
Gross weight, approx. m 33 kg
Net weight, approx. m 32.5 kg
Tender text

System for water supply, irrigation and rainwater utilisation; consisting of a self-priming pump with up to 7 m, a pressure tank and pressure switch with automatic start/stop function

Materials
Pump housing Grey cast iron
Impeller Stainless steel
Shaft Steel
Shaft seal BQ1PFF
Gasket material NBR
Operating Data
Min. fluid temperature Tmin 5 °C
Max. fluid temperature Tmax 35 °C
Maximum operating pressure p 6.0 bar
Discharge port G 1
Max. ambient temperature Tmax 40 °C
Motor data
Rated current IN 5 A
Rated speed n 2850 1/min
Mains connection 1~230 V, 50 Hz
Insulation class F
Electromagnetic compatibility EN 61000-6-1, -2, -3, -4
Protection class IPX4
Installation dimensions
Pipe connection on the suction side DNs G 1
Pipe connection on the discharge side DNd G 1
Ordering information
Net weight, approx. m 32.5 kg
Brand Wilo
Product description Initial JET System 4-4-50
Article number 4168024
Documents

Installation and operating instructions

Wilo-Initial JET System

Article Number 4168384
Edition 2023-04
Number of pages 16
Language en
PDF (590 KB)

Certification booklet

Wilo-Initial-Jet

Article Number 4251852
Edition 2021-09
Number of pages 12
Language ar, az, ba, bg, cs, da, de, el, en, es, et, fi, fr, ga, hr, hu, it, ko, lt, lv, mk, nl, no, pl, pt, ro, ru, sk, sl, sq, sr, sv, tr, uk, zh
PDF (3 MB)

Group Statement

Group Statement REACH

Edition 2021-05
Number of pages 5
Language language neutral
PDF (327 KB)
Accessory

In inlet mode (2)

In suction mode (1)

In suction mode with floating intake (9)

In suction mode with suction hose (3)

Fittings (2)

Hoses / hose joints (7)

Suction filter (4)

Valves/accessories (1)

Wall fixation/installation on a base (1)

Services

With Wilo as your partner, you can not only be sure of choosing high-quality product solutions, but also of benefiting from a comprehensive, worry-free package of well thought-out services. We collaborate to develop a service concept tailored to your individual needs; with our expertise and personal consultancy, we make sure that the operation of your systems is as energy-efficient, reliable and economical as possible. All the while our competent Wilo service technicians are ready to assist you with fast, reliable and on-time support.

Read more

Recommended services

Maintenance
Maintenance BASIC Booster Set 1-2 pumps
    
2160453

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections, maintenance and repair carried out by WILO SE’s own customer service. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Inspection of any diaphragm expansion tanks in the system (not filling)
  • Review and, if necessary, adjustment of the system parameters
  • Drawing up a maintenance and repair report

WILO SE schedules and organises initial maintenance and repairs. Further customised maintenance and repair services are possible after the first maintenance and repairs are conducted.

Maintenance COMFORT Booster Set 1-2 pumps
    
2160468

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections, maintenance and repair carried out by WILO SE’s own customer service. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Review and, if necessary, adjustment of the system parameters
  • Drawing up a maintenance and repair report
  • Consumables are included in the price
  • Small repairs are included in the maintenance and repair price
  • No labour and travel expenses are charged for deployments between maintenance and repair intervals (during normal operating hours)

WILO SE schedules and organises initial maintenance and repairs. Further customised maintenance and repair services are possible after the first maintenance and repairs are conducted. The quoted price refers to the initial maintenance and repair offered.

-NET-

Maintenance PREMIUM Booster Set 1-2 pumps
    
2160483

In order to ensure and guarantee operational reliability of the pumps/systems, it is recommended to have regular and DIN-compliant inspections and maintenance carried out by the works' own WILO SE Customer Service Department. The tasks are carried out in accordance with DIN 31051 / DIN EN 13306. The tasks comprise the following points:

  • Visual inspection of the pumps/systems
  • Mechanical check
  • Electrical check
  • Testing and possible filling of pressure vessels that may be on hand
  • Checking the system parameters
  • Creating a maintenance protocol
  • Consumable materials are included in the contract price
  • Elimination of payroll and travel expenses for deployments between maintenance intervals (during and outside normal service hours)
  • Software updates
  • Wearing parts included

Scheduling and organisation are performed by WILO SE. Other individual maintenance offers are possible on request.

Commissioning
Commissioning Booster Set 1-2 pumps
    
2216414

For perfect functioning of the pump(s) / system(s), it is recommended to have the commissioning carried out by the works' own WILO SE Customer Service Department. Optimum setting and efficient operation of the system are ensured as a result. Commissioning is comprised of the following points:

  • Commissioning of system(s) according to checklist
  • Parameterisation and setting of switchgear
  • Testing and adaptation of initial compressing of pressure tanks (filling up to 80 litres incl.)
  • Functional check of fitted system(s)
  • Practice-oriented operation instruction
  • Wilo commissioning protocol

The price for commissioning only applies to system(s) which have been installed in accordance with the installation and operating instructions and state-of-the-art technology. No costs for any materials which may be required are included.

-NET-

More suitable services

Wilo-Live Assistant
Wilo-Live Assistant Service
    
2216415

The Wilo-Live Assistant is a technical advisor at your side during pump service. By using the Wilo-Live Assistant, our expert advisers can support you in the boiler or equipment room via video transmission – live and in real time. You use your smartphone to show the installation set-up, while the Wilo expert follows everything on their screen. They can see the components as well as other details and can thus determine where the fault or breakdown originates. We prevent downtime and ensure operational reliability of your pumps and systems!

The Wilo-Live Assistant includes:

  • Interactive live support via video chat
  • Direct contact with an expert
  • Just-in-time solution to ensure maximum operational reliability of your pumps and systems
Extended Warranty
Extended Warranty Booster Set 1-2 pumps
    
2216416

In combination of a new pump or system Wilo offers an extended warranty of up to five years in combination with commissioning and maintenance by the Wilo Service.

Extended warranty includes:

  • Full protection and predictable cost security
  • Regular maintenance work by the Wilo Service
Supervision
Supervision Booster Set 1-2 pumps
    
2216412

Wilo supports during the concept phase to ensure quality work and cost efficiency. Our competent and qualified Wilo Service will support you with recommendations and technical advice throughout the entire project.

Supervision includes:

  • Regular on-site visits ensure the quality of information and advice
  • Technical consultancy, also available on site
  • Status report with recommendations after the visit
  • Comprehensive support from a Wilo expert
Installation
Installation Booster Set 1-2 pumps
    
2216413

The Wilo service offers installation of our pumps or pumping systems. We offer an end-to-end process from gathering information on site to installing our product in the overall plant. An optimal installation set-up and the interaction of various individual factors lay the foundation for long-term operational safety.

Installation includes:

  • Professional inspection
  • Provision of components/materials from Wilo and third-party suppliers
  • Installation of pipelines and electronics
  • Test runs
System Optimisation
System Optimisation Booster Set 1-2 pump
    
2216410

The Wilo Service offers proactive system optimisation by optimising settings and doing minor adjustments to ensure operational reliability. System Optimisation includes among others:

  • Overhaul of pumps/systems to restore full performance
  • Addition of new technologies or functions in older systems to save on capital expenditures (retrofitting)
Energy Solutions
Energy Solutions Booster Set 1-2 pumps
    
2216411

Wilo Service offers a proactive support to point out possible energy savings. Our service creates an overview of all installed assets to show how the energy consumption of pumps or systems can be reduced. We offer targeted consultancy and analysis, including the involvement of subsidies as well as comprehensive support around the changeover to high-efficiency technologies. Wilo-Energy solution includes:

  • Detailed assessment of the life cycle costs (LCC analysis)
  • Energy audit including information about energy saving potential
  • Proactive recommendation of replacement options
  • Improving the environmental performance of your system
  • Support in the changeover to Wilo high-efficiency pumps
Repair
Repair Booster Set 1-2 pumps
    
2216417

Wilo Service draws on their competence and experience while consulting on site to decide whether the pump can actually be repaired on site or has to be sent in for a factory repair. Wilo also provides spare parts or a replacement pump to restore the operational reliability of the system.

Repair includes:

  • Verification and elimination of error causes by experienced Wilo experts
  • Non-binding estimate for repairs
  • Electric-hydraulic test run to ensure correct data regarding functionality, quality and performance of the pump or system
  • Coating of various pump or system components for an optimised efficiency factor
  • Use of genuine spare parts only
  • Documentation of the repair in the service report